h1

h2

h3

h4

h5
h6


001     1009543
005     20250603093820.0
024 7 _ |2 HBZ
|a HT031046116
024 7 _ |2 Laufende Nummer
|a 44211
024 7 _ |2 datacite_doi
|a 10.18154/RWTH-2025-03519
037 _ _ |a RWTH-2025-03519
041 _ _ |a English
082 _ _ |a 610
100 1 _ |0 P:(DE-588)1365088790
|a Chen, Qingping
|b 0
|u rwth
245 _ _ |a Development and implementation of accelerated multiple-quantum-filtered sodium magnetic resonance imaging using compressed sensing at ultra-high field
|c vorgelegt von Qingping Chen
|h online
260 _ _ |a Aachen
|b RWTH Aachen University
|c 2025
300 _ _ |a 1 Online-Ressource : Illustrationen
336 7 _ |0 2
|2 EndNote
|a Thesis
336 7 _ |0 PUB:(DE-HGF)11
|2 PUB:(DE-HGF)
|a Dissertation / PhD Thesis
|b phd
|m phd
336 7 _ |2 BibTeX
|a PHDTHESIS
336 7 _ |2 DRIVER
|a doctoralThesis
336 7 _ |2 DataCite
|a Output Types/Dissertation
336 7 _ |2 ORCID
|a DISSERTATION
500 _ _ |a Veröffentlicht auf dem Publikationsserver der RWTH Aachen University
502 _ _ |a Dissertation, Rheinisch-Westfälische Technische Hochschule Aachen, 2025
|b Dissertation
|c Rheinisch-Westfälische Technische Hochschule Aachen
|d 2025
|g Fak10
|o 2025-04-02
520 3 _ |a Natrium (23Na) spielt eine entscheidende Rolle bei zellulären Stoffwechselprozessen durch die Regulierung der Natrium-Kalium-Pumpe, die auf Kosten der Energie einen großen Gradienten zwischen intrazellulären und extrazellulären Natriumkonzentrationen aufrechterhält. Eine zelluläre Dysfunktion kann zu einer erhöhten intrazellulären Natriumkonzentration führen, wohingegen die extrazelluläre Natriumkonzentration aufgrund der Gewebeperfusion weitgehend unverändert bleibt. Daher verspricht intrazelluläres Natrium als direkte Verbindung zur Zellintegrität und Gewebelebensfähigkeit Einblicke in pathologische Prozesse. Mit der konventionellen Natrium-Magnetresonanztomographie (MRT) mit einem einzigen Hochfrequenzimpuls kann nur das gesamte Natrium nachgewiesen werden. Basierend auf der quadrupolaren Natur des Natriumkerns wird eine fortschrittliche Technik, die mehrfach quantengefilterte (MQF) Natrium-MRT, vorgeschlagen, um eingeschränktes (hauptsächlich intrazelluläres) Natrium zu überwachen. Die klinische Anwendung der MQF-Natrium-MRT wird jedoch durch die relativ geringe Bildqualität und die damit verbundenen langen Aufnahmezeiten erschwert. Ziel dieser Arbeit ist es, die Einschränkungen der MQF-Natrium-MRT zu mildern, indem zwei Aspekte genutzt werden: Datenerfassung und Bildrekonstruktion. In Bezug auf die Datenerfassung optimierte diese Arbeit die verbesserte simultane Einzelquanten- und Dreifachquanten-gefilterte Bildgebung der 23NA-Sequenz (SISTINA) unter Verwendung eines hocheffizienten nicht-kartesischen Abtastschemas. Die qualitative Validierung dieser Sequenzoptimierung wurde durch den Vergleich der optimierten Sequenz mit einer herkömmlichen erweiterten SISTINA-Sequenz in Phantommessungen bei 7T durchgeführt. Die Optimierung verbesserte die visuelle Leistung von Bildern mit ultrakurzer Echozeit erheblich, während die visuelle Qualität von MQF-Bildern erhalten blieb und Inkohärenz in den Rohdaten für die Anwendung der Compressed Sensing (CS)-Beschleunigung eintrat. In Bezug auf die Bildrekonstruktion wendete diese Arbeit CS an, um verbesserte SISTINA-Akquisitionen zu beschleunigen, indem die Bildsparsität ausgenutzt wurde, um inkohärente Unterabtastungsartefakte zu kompensieren. Die quantitative Validierung der CS-Beschleunigung wurde durchgeführt, indem die unterabgetasteten CS-basierten Rekonstruktionen mit vollständig abgetasteten und unterabgetasteten standardmäßigen Non-Uniform Fast Fourier Transform (NUFFT)-Rekonstruktionen sowohl in Phantom- als auch in vivo-Messungen bei 7T verglichen wurden. Im Vergleich zu NUFFT beschleunigte CS in dieser Studie die Verbesserung von SISTINA bei 7T um das Zweifache bei reduziertem Rauschpegel, während gleichzeitig primäre Strukturinformationen, angemessene Gewichtungen für Gesamt- und Kompartiment-Natrium und eine relativ genaue In-vivo-Quantifizierung erhalten blieben.
|l ger
520 _ _ |a Sodium (23Na) plays a critical role in cellular metabolic processes via the regulation of the sodium-potassium pump, which maintains a large gradient between intracellular and extracellular sodium concentrations at the expense of energy. Cellular dysfunction can lead to an elevated intracellular sodium concentration, whereas the extracellular sodium concentration remains primarily unchanged due to tissue perfusion. Therefore, intracellular sodium, as a direct link to cell integrity and tissue viability, promises means for an insight into pathological processes.Conventional sodium Magnetic Resonance Imaging (MRI) with a single radiofrequency pulse can only detect total sodium. Based on the quadrupolar nature of the sodium nucleus, an advanced technique, Multiple-Quantum-Filtered (MQF) sodium MRI, is proposed to monitor restricted (mainly intracellular) sodium. However, the clinical application of MQF sodium MRI is hampered by the relatively low image quality and associated long acquisition times. This thesis aims to mitigate the limitations of MQF sodium MRI by exploiting two aspects: data acquisition and image reconstruction. Regarding data acquisition, this thesis optimised the enhanced Simultaneous Single-quantum and Triple-quantum-filtered imaging of 23NA (SISTINA) sequence using a highly efficient non-Cartesian sampling scheme. Qualitative validation of this sequence optimisation was conducted by comparing the optimised sequence with a conventional enhanced SISTINA sequence in phantom measurements at 7T. The optimisation greatly improved the visual performance of ultra-short-echo-time images, while maintaining the visual quality of MQF images and introducing incoherence in raw data for the application of Compressed Sensing (CS) acceleration. Regarding image reconstruction, this thesis applied CS to accelerate enhanced SISTINA acquisitions by exploiting image sparsity to compensate for incoherent under sampling artefacts. Quantitative validation of the CS acceleration was performed by comparing the under sampled CS-based reconstructions with fully sampled and under sampled standard Non-Uniform Fast Fourier Transform (NUFFT) reconstructions in both phantom and in vivo measurements at 7T. Compared to NUFFT, CS accelerated enhanced SISTINA by up to twofold at 7T in this study with reduced noise levels, while maintaining primary structural information, reasonable weightings towards total and compartmental sodium and relatively accurate in vivo quantification.
|l eng
588 _ _ |a Dataset connected to Lobid/HBZ
591 _ _ |a Germany
700 1 _ |0 P:(DE-82)IDM02632
|a Shah, Nadim Joni
|b 1
|e Thesis advisor
|u rwth
700 1 _ |0 P:(DE-588)131981609
|a Veselinovic, Tanja
|b 2
|e Thesis advisor
|u rwth
856 4 _ |u https://publications.rwth-aachen.de/record/1009543/files/1009543.pdf
|y OpenAccess
856 4 _ |u https://publications.rwth-aachen.de/record/1009543/files/1009543_source.doc
|y Restricted
856 4 _ |u https://publications.rwth-aachen.de/record/1009543/files/1009543_source.docx
|y Restricted
856 4 _ |u https://publications.rwth-aachen.de/record/1009543/files/1009543_source.odt
|y Restricted
909 C O |o oai:publications.rwth-aachen.de:1009543
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-588)1365088790
|a RWTH Aachen
|b 0
|k RWTH
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-82)IDM02632
|a RWTH Aachen
|b 1
|k RWTH
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-588)131981609
|a RWTH Aachen
|b 2
|k RWTH
914 1 _ |y 2025
915 _ _ |0 StatID:(DE-HGF)0510
|2 StatID
|a OpenAccess
920 1 _ |0 I:(DE-82)535000-5_20140620
|k 535000-5 ; 934010
|l Lehr- und Forschungsgebiet Physik der Magnetresonanztomographie in den Neurowissenschaften (FZ Jülich)
|x 0
980 1 _ |a FullTexts
980 _ _ |a I:(DE-82)535000-5_20140620
980 _ _ |a UNRESTRICTED
980 _ _ |a VDB
980 _ _ |a phd


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21