h1

h2

h3

h4

h5
h6
001012085 001__ 1012085
001012085 005__ 20250630125555.0
001012085 0247_ $$2HBZ$$aHT031167169
001012085 0247_ $$2Laufende Nummer$$a44361
001012085 0247_ $$2datacite_doi$$a10.18154/RWTH-2025-04854
001012085 037__ $$aRWTH-2025-04854
001012085 041__ $$aEnglish
001012085 082__ $$a610
001012085 1001_ $$0P:(DE-588)1368646905$$aMohapatra, Saurav Ranjan$$b0$$urwth
001012085 245__ $$aDevelopment and non-invasive monitoring of tissue-engineered cardiovascular implants$$cvorgelegt von Saurav Ranjan Mohapatra, M. Sc.$$honline
001012085 260__ $$aAachen$$bRWTH Aachen University$$c2025
001012085 300__ $$a1 Online-Ressource : Illustrationen
001012085 3367_ $$02$$2EndNote$$aThesis
001012085 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd
001012085 3367_ $$2BibTeX$$aPHDTHESIS
001012085 3367_ $$2DRIVER$$adoctoralThesis
001012085 3367_ $$2DataCite$$aOutput Types/Dissertation
001012085 3367_ $$2ORCID$$aDISSERTATION
001012085 502__ $$aDissertation, Rheinisch-Westfälische Technische Hochschule Aachen, 2025, Kumulative Dissertation$$bDissertation$$cRheinisch-Westfälische Technische Hochschule Aachen$$d2025$$gFak10$$o2025-05-08
001012085 500__ $$aVeröffentlicht auf dem Publikationsserver der RWTH Aachen University
001012085 5203_ $$aKardiovaskuläre Erkrankungen gehören weltweit zu den häufigsten Todesursachen und erfordern Fortschritte bei den Behandlungsmöglichkeiten. Synthetische Gefäßtransplantate und mechanische Herzklappen haben Einschränkungen wie eine hohe Thromboseneigung und die Notwendigkeit wiederholter Operationen. Tissue-engineerte Gefäßtransplantate (TEVGs) und Herzklappen (TEHVs) bieten vielversprechende Alternativen aufgrund ihrer Umbaukapazitäten und ihres Potenzials zur Integration in das Wirtsgewebe. Die Gewährleistung der mechanischen Festigkeit, die schnelle Reifung der extrazellulären Matrix (ECM) und die Echtzeitüberwachung stellen jedoch nach wie vor eine Herausforderung dar. Darüber hinaus sind ein effektives Management des Lebenszyklus von Implantaten und eine langfristige Nachsorge entscheidend für den klinischen Erfolg. Unsere Forschung zielt darauf ab, die Entwicklung von TEVGs und TEHVs durch fortschrittliche Bioreaktorkonditionierung und 7T-MRT-Überwachung zu beschleunigen und sie der klinischen Anwendung näher zu bringen. Die erste Studie hatte zum Ziel, die Produktion von TEVGs zu verbessern, indem die normalerweise mehrere Wochen dauernde Konditionierungszeit des Bioreaktors deutlich verkürzt wurde. Als Zellträger wurde ein biologisch abbaubares Polymilchsäure-Co-Glykolsäure (PLGA)-Gerüst in Kombination mit einem copolymerverstärkten Fibrin-Gel verwendet. Durch die Kombination von Textilien, biologisch abbaubaren Fasern und Hydrogelmatrix konnte die Konditionierungszeit auf nur 4 Tage verkürzt werden, während gleichzeitig eine erhebliche Reifung der extrazellulären Matrix (ECM) und mechanische Festigkeit erreicht wurde. Mechanische Tests ergaben, dass der Berstdruck (617±85 mm Hg) und die Zugfestigkeit des TEVG die von nativen Arterien übertrafen. Darüber hinaus ermöglichte der Einbau von MRT-Kontrastmitteln in das Gerüst eine nicht-invasive In-vitro-Überwachung des Gerüstabbaus mittels 7T-MRT, was wertvolle Einblicke in den Remodellierungsprozess ermöglichte. Die zweite Studie konzentrierte sich auf die Entwicklung eines pneumatisch angetriebenen multimodalen Bioreaktors, der für die MRT- und Ultraschallbildgebung für tissue-engineerte Herzklappen (TEHVs) optimiert wurde. Ein speziell angefertigter Bioreaktor, der für den dynamischen Betrieb innerhalb einer 72-mm-Bohrung einer 7T-MRT-Spule ausgelegt ist, ermöglichte die Echtzeit-Überwachung der TEHV-Funktionalität, ohne MRT-Interferenzen zu verursachen. TEHVs wurden aus einem Gerüst aus Polyethylenterephthalat (PET) und menschlichen Arterienzellen hergestellt, die unter physiologischen Bedingungen konditioniert wurden. Das Bioreaktorsystem erleichterte die Produktion von ECM-Komponenten, einschließlich Kollagen und Aktin der glatten Muskulatur, und gewährleistete gleichzeitig eine Besiedlung mit Endothelzellen. MRI-Bewegungskompensationstechniken und Ultraschallbildgebung erfassten erfolgreich die dynamische Bewegung der Herzklappen, was die Kompatibilität dieses neuartigen Systems für die Längsschnittüberwachung weiter unter Beweis stellte. Zusammenfassend lassen diese beiden Studien das Potenzial von tissue-engineerten kardiovaskulären Implantaten für den künftigen klinischen Einsatz erkennen. Durch die drastische Verkürzung der Konditionierungszeit von TEVGs und die Möglichkeit der dynamischen Echtzeit-Bildgebung von TEHVs sind wir der Entwicklung von Implantaten nähergekommen, die nicht nur funktional und haltbar sind, sondern auch während ihrer Entwicklung und nach der Implantation nicht-invasiv überwacht werden müssen. Diese Fortschritte sind ein bedeutender Schritt auf dem Weg zur Entwicklung kardiovaskulärer Implantate, die effizient in die klinische Praxis umgesetzt werden können, um die Ergebnisse für die Patienten zu verbessern und den Bedarf an wiederholten Eingriffen zu verringern.$$lger
001012085 520__ $$aCardiovascular diseases (CVD) are among the leading causes of death globally, requiring advancements in treatment options. Synthetic vascular grafts and mechanical heart valves have limitations such as thrombosis and the need for repeated surgeries. Tissue-engineered vascular grafts (TEVGs) and heart valves (TEHVs) offer promising alternatives due to their remodeling capabilities and potential to integrate with host tissues. However, challenges remain in ensuring mechanical strength, rapid extracellular matrix (ECM) maturation, and real-time monitoring. Additionally, effective implant life cycle management and long-term follow-up are critical for clinical success. Our research aims to accelerate the development of TEVGs and TEHVs through advanced bioreactor conditioning and 7T MRI monitoring, bringing them closer to clinical application.The first study aimed to enhance the production of TEVGs by significantly shortening the bioreactor conditioning time, which normally takes several weeks. A biodegradable polylactic-co-glycolic acid (PLGA) scaffold, combined with a copolymer-reinforced fibrin gel, was used as a cell carrier. By utilizing the combination of textile, biodegradable fiber, and hydrogel matrix, the conditioning time was reduced to just 4 days, while achieving substantial extracellular matrix (ECM) maturation and mechanical strength. Mechanical testing showed the TEVG’s burst pressure (617±85 mm Hg) and tensile strength exceeded that of native arteries. Additionally, the incorporation of MRI contrast agents into the scaffold allowed for non-invasive in vitro monitoring of scaffold degradation using 7T MRI, providing valuable insights into the remodeling process. The second study focused on the development of a pneumatically driven multimodal bioreactor optimized for MRI and ultrasound imaging for tissue-engineered heart valves (TEHVs). A custom-built bioreactor, designed to operate dynamically within a 72 mm bore of a 7T MRI coil, enabled the real-time monitoring of TEHV functionality without causing MRI interference. TEHVs were constructed using a polyethylene terephthalate (PET) scaffold and human arterial cells, conditioned under physiological conditions. The bioreactor system facilitated the production of ECM components, including collagen and smooth muscle actin, while ensuring a monolayer of endothelial cells. MRI motion compensation techniques and ultrasound imaging successfully captured the dynamic movement of the heart valves, further proving the compatibility of this novel system for longitudinal monitoring.In conclusion, these two studies underscore the potential of tissue-engineered cardiovascular implants for future clinical use. By drastically reducing the conditioning time of TEVGs and enabling dynamic real-time imaging of TEHVs, we have moved closer to developing implants that are not only functional and durable but also capable of being non-invasively monitored during their development and post-implantation phases. These advancements represent a significant step toward creating cardiovascular implants that can be efficiently translated to clinical practice, improving patient outcomes and reducing the need for repeated interventions.$$leng
001012085 536__ $$0G:(GEPRIS)403039938$$aDFG project G:(GEPRIS)403039938 - TexValveMonitoring - Multimodale longitudinale Bildgebung von biohybriden Herzklappen (403039938)$$c403039938$$x0
001012085 588__ $$aDataset connected to Lobid/HBZ
001012085 591__ $$aGermany
001012085 653_7 $$aHerzklappen
001012085 653_7 $$aMRI
001012085 653_7 $$aMRT
001012085 653_7 $$acardiovascular implants
001012085 653_7 $$aheart valves
001012085 653_7 $$akardiovaskulären Implantate
001012085 653_7 $$atissue engineering
001012085 7001_ $$0P:(DE-82)005708$$aApel, Christian$$b1$$eThesis advisor$$urwth
001012085 7001_ $$0P:(DE-82)IDM03844$$aKiessling, Fabian$$b2$$eThesis advisor$$urwth
001012085 7870_ $$0RWTH-2022-09617$$iRelatedTo
001012085 7870_ $$0RWTH-2024-10897$$iRelatedTo
001012085 8564_ $$uhttps://publications.rwth-aachen.de/record/1012085/files/1012085.pdf$$yOpenAccess
001012085 8564_ $$uhttps://publications.rwth-aachen.de/record/1012085/files/1012085_source.doc$$yRestricted
001012085 8564_ $$uhttps://publications.rwth-aachen.de/record/1012085/files/1012085_source.docx$$yRestricted
001012085 8564_ $$uhttps://publications.rwth-aachen.de/record/1012085/files/1012085_source.odt$$yRestricted
001012085 909CO $$ooai:publications.rwth-aachen.de:1012085$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
001012085 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
001012085 9141_ $$y2025
001012085 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-588)1368646905$$aRWTH Aachen$$b0$$kRWTH
001012085 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)005708$$aRWTH Aachen$$b1$$kRWTH
001012085 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM03844$$aRWTH Aachen$$b2$$kRWTH
001012085 9201_ $$0I:(DE-82)811001-1_20140620$$k811001-1 ; 923510$$lInstitut und Lehrstuhl für Angewandte Medizintechnik$$x0
001012085 961__ $$c2025-06-27T15:34:22.019759$$x2025-05-21T01:19:30.921676$$z2025-06-27T15:34:22.019759
001012085 9801_ $$aFullTexts
001012085 980__ $$aI:(DE-82)811001-1_20140620
001012085 980__ $$aUNRESTRICTED
001012085 980__ $$aVDB
001012085 980__ $$aphd