h1

h2

h3

h4

h5
h6


001     1024771
005     20260205060015.0
024 7 _ |2 HBZ
|a HT031374528
024 7 _ |2 Laufende Nummer
|a 44968
024 7 _ |2 datacite_doi
|a 10.18154/RWTH-2026-00326
037 _ _ |a RWTH-2026-00326
041 _ _ |a German
082 _ _ |a 610
100 1 _ |0 P:(DE-588)1386578355
|a Heinen, Katharina Svenja
|b 0
|u rwth
245 _ _ |a Mehrwert eines digitalen Analysesystems für die Bewertung von Zahnpräparationen für eine vollverblendete Krone in der vorklinischen Ausbildung
|c vorgelegt von Katharina Svenja Heinen, geborene Merkel
|h online
260 _ _ |a Aachen
|b RWTH Aachen University
|c 2025
260 _ _ |c 2026
300 _ _ |a 1 Online-Ressource : Illustrationen
336 7 _ |0 2
|2 EndNote
|a Thesis
336 7 _ |0 PUB:(DE-HGF)11
|2 PUB:(DE-HGF)
|a Dissertation / PhD Thesis
|b phd
|m phd
336 7 _ |2 BibTeX
|a PHDTHESIS
336 7 _ |2 DRIVER
|a doctoralThesis
336 7 _ |2 DataCite
|a Output Types/Dissertation
336 7 _ |2 ORCID
|a DISSERTATION
500 _ _ |a Veröffentlicht auf dem Publikationsserver der RWTH Aachen University 2026
502 _ _ |a Dissertation, Rheinisch-Westfälische Technische Hochschule Aachen, 2025
|b Dissertation
|c Rheinisch-Westfälische Technische Hochschule Aachen
|d 2025
|g Fak10
|o 2025-12-01
520 3 _ |a Ziel: Diese Studie untersucht den Mehrwert einer digitalen Analysesoftware für die Beurteilung von studentischen Kronenpräparationen gegenüber der konventionellen visuellen Beurteilung mittels Checkliste.Material und Methode: Zwanzig von Studierenden präparierte Kunststoffzähne wurden von zwölf Zahnärzten beurteilt. Die Beurteilung in der ersten Sitzung erfolgte konventionell anhand einer Checkliste mit zwölf Kriterien. Nach einer Kalibrierung der Prüfer und Schulung zur Nutzung der Analysesoftware wurde in der zweiten Sitzung ein Teil der Präparationen erneut visuell beurteilt (n=10) und ein anderer Teil (n=5) mit der Software „prepCheck“ (Sirona) bewertet. Die statistischen Auswertungen bezogen sich auf Zeitaufwand sowie Inter- und Intrarater-Reliabilität.Ergebnisse: Die Ergebnisse zeigen, dass die konventionelle Methode mit Checkliste eine hohe Interrater-Reliabilität aufweist (Korrelationskoeffizient 0,88), jedoch Schwankungen in der Intrarater-Reliabilität. Die Bewertung einzelner Parameter wie Approximalabstand war konsistenter, während komplexere Kriterien wie okklusale und zirkuläre Reduktion signifikante Variabilität aufwiesen. Mit „prepCheck“ wurden fünf der zwölf Kriterien signifikant höher bewertet, bei tendenziell geringerer Standardabweichung. Der Zeitaufwand für prepCheck lag jedoch etwa siebenmal höher. Schlussfolgerungen: Die konventionelle Methode bietet trotz Checkliste oft keine konsistente Intrarater-Reliabilität, was zu subjektiven Bewertungen in vorklinischen Kursen führen kann. Die hohe Interrater-Reliabilität deutet jedoch darauf hin, dass Kalibrierungen und Checklisten Objektivität fördern. Die Analysesoftware prepCheck führte zu objektiveren, konsistenteren Bewertungen mit weniger strengen Urteilen und geringerer Streuung, was eine höhere Bewertungsgenauigkeit nahelegt. Trotz des hohen Zeitaufwands ist der Einsatz solcher Software im zahnmedizinischen Unterricht vielversprechend, besonders zur Förderung digitaler Kompetenz und Leistungsbewertung
|l ger
520 _ _ |a Objective: This study examines the added value of a digital analysis software for evaluating student crown preparations compared to conventional visual assessment using a checklist.Materials and Methods: Twenty typodont teeth prepared by students were assessed by twelve dentists. In the first session, assessments were conducted conventionally using a checklist with twelve criteria. After calibrating the examiners and training them to use the analysis software, in the second session, part of the preparations was re-evaluated visually (n=10), while another part (n=5) was evaluated using the software “prepCheck” (Sirona). Statistical analyses focused on time required as well as inter- and intra-rater reliability.Results: The results show that the conventional method with a checklist demonstrated high inter-rater reliability (correlation coefficient 0.88), yet revealed fluctuations in intra-rater reliability. Assessment of individual parameters, such as proximal distance, was more consistent, while more complex criteria, such as occlusal and circumferential reduction, showed significant variability. Using “prepCheck,” five of the twelve criteria were rated significantly higher, with a generally lower standard deviation. However, the time required for prepCheck was approximately seven times higher. Conclusions: Despite the checklist, the conventional method often lacks consistent intra-rater reliability, which can lead to subjective evaluations in preclinical courses. However, the high inter-rater reliability suggests that calibrations and checklists help foster objectivity. The prepCheck analysis software resulted in more objective and consistent evaluations, with less stringent judgments and reduced variability, suggesting greater accuracy in assessment. Despite the high time investment, using such software in dental education is promising, particularly for promoting digital competence and consistent performance evaluation.
|l eng
588 _ _ |a Dataset connected to Lobid/HBZ
591 _ _ |a Germany
653 _ 7 |a Beurteilung von Zahnmedizinstudierenden
653 _ 7 |a assessment of dental students
700 1 _ |0 P:(DE-82)005107
|a Wolfart, Stefan
|b 1
|e Thesis advisor
|u rwth
700 1 _ |0 P:(DE-82)177003
|a Wolf, Michael
|b 2
|e Thesis advisor
|u rwth
856 4 _ |u https://publications.rwth-aachen.de/record/1024771/files/1024771.pdf
|y OpenAccess
856 4 _ |u https://publications.rwth-aachen.de/record/1024771/files/1024771_source.docx
|y Restricted
909 C O |o oai:publications.rwth-aachen.de:1024771
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-588)1386578355
|a RWTH Aachen
|b 0
|k RWTH
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-82)005107
|a RWTH Aachen
|b 1
|k RWTH
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-82)177003
|a RWTH Aachen
|b 2
|k RWTH
914 1 _ |y 2026
915 _ _ |0 StatID:(DE-HGF)0510
|2 StatID
|a OpenAccess
920 1 _ |0 I:(DE-82)542000-2_20140620
|k 542000-2 ; 937710
|l Klinik und Lehrstuhl für zahnärztliche Prothetik, Implantologie und Biomaterialien
|x 0
980 1 _ |a FullTexts
980 _ _ |a I:(DE-82)542000-2_20140620
980 _ _ |a UNRESTRICTED
980 _ _ |a VDB
980 _ _ |a phd


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21