h1

h2

h3

h4

h5
h6
000444036 001__ 444036
000444036 005__ 20230515133751.0
000444036 0247_ $$2HSB$$a999910368126
000444036 0247_ $$2ISBN$$a978-84-697-1815-5
000444036 0247_ $$2datacite_doi$$a10.18154/RWTH-CONV-206054
000444036 037__ $$aRWTH-CONV-206054
000444036 041__ $$aEnglish
000444036 082__ $$a620
000444036 1001_ $$0P:(DE-82)IDM00367$$aWolisz, Henryk Stefan$$b0$$urwth
000444036 1112_ $$aSustainable Buildings$$cBarcelona$$d2014-10-28 - 2014-10-30$$gWorld SB 4$$wSpain
000444036 245__ $$aFloor-integrated HVAC-systems for zonal supply of multifunctional buildings$$honline, media combination
000444036 260__ $$a[s.l.]$$bGreen Building Council España$$c2014
000444036 260__ $$c2018
000444036 29510 $$aWorld SB 4 : Sustainable Buildings 2014 ; Results ... ; Barcelona, Spain, October 28th-30th 2014
000444036 300__ $$a1-8
000444036 3367_ $$033$$2EndNote$$aConference Paper
000444036 3367_ $$0PUB:(DE-HGF)7$$2PUB:(DE-HGF)$$aContribution to a book
000444036 3367_ $$0PUB:(DE-HGF)8$$2PUB:(DE-HGF)$$aContribution to a conference proceedings$$bcontrib$$mcontrib
000444036 3367_ $$2BibTeX$$aINPROCEEDINGS
000444036 3367_ $$2DRIVER$$aconferenceObject
000444036 3367_ $$2DataCite$$aOutput Types/Conference Paper
000444036 3367_ $$2ORCID$$aCONFERENCE_PAPER
000444036 500__ $$aZweitveröffentlicht auf dem Publikationsserver der RWTH Aachen University 2018
000444036 536__ $$0G:(DE-82)ZUK2-BF-OPBF051$$aOPBF051 - Sustainable Buildings of the Future$$cZUK2-BF-OPBF051$$x0
000444036 536__ $$0G:(DE-82)ZUK2-BF$$aERS Boost Fund (ZUK2) - Exploratory Research Space: Boost Fund (2) zur Förderung neuer interdisziplinärer Forschungsfelder mit hohem Potenzial (ZUK2-BF)$$cZUK2-BF$$x1
000444036 536__ $$0G:(DE-82)ZUK2$$aZukunftskonzept II - Zukunftskonzept der RWTH Aachen University im Rahmen der zweiten Exzellenzinitiative (ZUK2)$$cZUK2$$x2
000444036 591__ $$aGermany
000444036 650_7 $$2SWD$$aGebäude
000444036 650_7 $$2SWD$$aGebäudetechnik
000444036 650_7 $$2SWD$$aHeizungstechnik
000444036 650_7 $$2SWD$$aLüftungssystem
000444036 650_7 $$2SWD$$aNachhaltige Entwicklung
000444036 650_7 $$2SWD$$aTechnische Gebäudeausrüstung
000444036 653_7 $$2eng$$aHVAC
000444036 653_7 $$2eng$$aheating
000444036 653_7 $$2eng$$amodular supply systems
000444036 653_7 $$2eng$$amultifunctional buildings
000444036 653_7 $$2eng$$asustainable building design
000444036 653_7 $$2eng$$aventilation
000444036 653_7 $$aIngenieurwissenschaften
000444036 7001_ $$0P:(DE-82)199071$$aAlbert, Anne Christine$$b1$$urwth
000444036 7001_ $$0P:(DE-82)IDM00655$$aPyschny, Dominik$$b2$$urwth
000444036 7001_ $$0P:(DE-82)IDM01104$$aClaßen, Martin$$b3$$urwth
000444036 7001_ $$0P:(DE-82)IDM00568$$aStreblow, Rita$$b4$$urwth
000444036 7001_ $$0P:(DE-82)IDM01533$$aMüller, Dirk$$b5$$urwth
000444036 7001_ $$0P:(DE-82)IDM00916$$aFeldmann, Markus$$b6$$urwth
000444036 7001_ $$0P:(DE-82)IDM00754$$aHegger, Josef$$b7$$urwth
000444036 8564_ $$uhttps://publications.rwth-aachen.de/record/444036/files/444036.pdf$$yOpenAccess
000444036 8564_ $$uhttps://publications.rwth-aachen.de/record/444036/files/444036.gif?subformat=icon$$xicon$$yOpenAccess
000444036 8564_ $$uhttps://publications.rwth-aachen.de/record/444036/files/444036.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000444036 8564_ $$uhttps://publications.rwth-aachen.de/record/444036/files/444036.jpg?subformat=icon-700$$xicon-700$$yOpenAccess
000444036 909CO $$ooai:publications.rwth-aachen.de:444036$$popenaire$$popen_access$$pdriver$$pdnbdelivery$$pVDB
000444036 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00367$$aRWTH Aachen$$b0$$kRWTH
000444036 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)199071$$aRWTH Aachen$$b1$$kRWTH
000444036 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00655$$aRWTH Aachen$$b2$$kRWTH
000444036 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM01104$$aRWTH Aachen$$b3$$kRWTH
000444036 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00568$$aRWTH Aachen$$b4$$kRWTH
000444036 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM01533$$aRWTH Aachen$$b5$$kRWTH
000444036 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00916$$aRWTH Aachen$$b6$$kRWTH
000444036 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00754$$aRWTH Aachen$$b7$$kRWTH
000444036 9141_ $$y2014
000444036 9151_ $$0StatID:(DE-HGF)0031$$2StatID$$aPeer reviewed article$$x0
000444036 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000444036 9201_ $$0I:(DE-82)616400_20140620$$k616400$$lE.ON Energy Research Center$$x0
000444036 9201_ $$0I:(DE-82)419510_20140620$$k419510$$lLehrstuhl für Gebäude- und Raumklimatechnik$$x1
000444036 9201_ $$0I:(DE-82)311710_20140620$$k311710$$lLehrstuhl für Stahl- und Leichtmetallbau und Institut für Stahlbau$$x2
000444036 9201_ $$0I:(DE-82)311610_20140620$$k311610$$lLehrstuhl und Institut für Massivbau$$x3
000444036 961__ $$c2014-11-27$$x2014-11-17$$z2023-05-11
000444036 970__ $$ahsb999910368126
000444036 9801_ $$aFullTexts
000444036 980__ $$aConvertedRecord
000444036 980__ $$aI:(DE-82)311610_20140620
000444036 980__ $$aI:(DE-82)311710_20140620
000444036 980__ $$aI:(DE-82)419510_20140620
000444036 980__ $$aI:(DE-82)616400_20140620
000444036 980__ $$aUNRESTRICTED
000444036 980__ $$aVDB
000444036 980__ $$acontb
000444036 980__ $$acontrib