000462429 001__ 462429 000462429 005__ 20220422221640.0 000462429 0247_ $$2HBZ$$aHT018549562 000462429 0247_ $$2Laufende Nummer$$a34320 000462429 0247_ $$2OPUS$$a5277 000462429 0247_ $$2URN$$aurn:nbn:de:hbz:82-opus-52770 000462429 037__ $$aRWTH-CONV-145412 000462429 041__ $$aGerman 000462429 082__ $$a620 000462429 1001_ $$0P:(DE-82)016510$$aKirsten, Armin$$b0 000462429 245__ $$aOberflächenfunktionalisierung dentaler Zirkonoxid-Implantate mittels bioaktiver Glasbeschichtungen aus dem System SiO2-Na2O-K2O-CaO-MgO-P2O5$$cvorgelegt von Armin Kirsten$$honline, print 000462429 246_3 $$aSurface functionalization of dental zirconia implants using bioactive glass coatings from the system SiO2-Na2O-K2O-CaO-MgO-P2O5$$yEnglish 000462429 260__ $$aAachen$$bPublikationsserver der RWTH Aachen University$$c2015 000462429 300__ $$aVIII, 172 S. : Ill., graph. Darst. 000462429 3367_ $$02$$2EndNote$$aThesis 000462429 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd 000462429 3367_ $$2BibTeX$$aPHDTHESIS 000462429 3367_ $$2DRIVER$$adoctoralThesis 000462429 3367_ $$2DataCite$$aOutput Types/Dissertation 000462429 3367_ $$2ORCID$$aDISSERTATION 000462429 502__ $$aAachen, Techn. Hochsch., Diss., 2014$$gFak05$$o2014-10-24 000462429 5203_ $$aDentale Implantate weisen meist eine mikrostrukturierte Oberfläche auf, um das Einwachsen in den Knochen zu verbessern. Solche Mikrostrukturen können jedoch Entzündungen verursachen, wenn sie aus dem Kieferknochen in den Mundraum hineinragen. Eine degradierbare Glasbeschichtung auf einem glatten Zirkonoxid-Implantat könnte das Entzündungsrisiko hingegen verringern. Hierzu müsste sich die mikrostrukturierte Beschichtung im Speichel auflösen und eine glatte Oberfläche freigeben, welche dann leicht zu reinigen ist. Um diese Zielsetzung zu verfolgen, wurden neuartige Gläser synthetisiert, in Suspensionsform auf Zirkonoxid-Implantate aufgesprüht, gesintert und mikrostrukturiert. Die Verbundfestigkeit der Glasbeschichtungen sowie die Festigkeit des Zirkonoxids wurden untersucht. Bioaktivität, Degradation und Zellverträglichkeit der neuartigen Gläser wurden analysiert. Die Glasschichten überstanden Insertionsversuche unbeschadet. Der beschichtete Substratwerkstoff wies bei vergleichbarem Weibull-Modul eine deutlich höhere Festigkeit auf als das mikrostrukturierte Implantat-Material. Die Glasschichten waren bioaktiv, degradierbar und zytokompatibel. Diese In-Vitro-Ergebnisse offenbaren ein großes Potenzial der neuartigen Glasbeschichtungen für eine potenzielle Verminderung des Entzündungsrisikos bei dentalen Implantaten. Dies muss jedoch durch nachfolgende In-Vivo-Studien bestätigt werden.$$lger 000462429 520__ $$aDental implants usually exhibit a microstructured surface to improve their osseointegration behavior. However, such microstructures can cause inflammation once they protrude out of the jawbone into the oral cavity. A degradable glass coating on a smooth zirconia implant could reduce the risk of inflammation. Therefore the microstructured surface should degrade in saliva to uncover a smooth surface which is easily cleanable afterwards. To achieve this goal, novel glasses were synthesized, sprayed as slurry onto zirconia implants, sintered and microstructured. Bond strength of the glass coatings and bending strength of the substrate material was investigated. Bioactivity, degradation behavior and cytocompatibility of the glasses were analyzed. The novel glass coatings survived the insertion tests unscathed. The coated zirconia showed a distinct higher strength with a comparable Weibull modulus compared to the microstructured implant material. The glass coatings were bioactive, degradable and cytocompatible. These in vitro results reveal a high potential of the novel glass coatings for a reduction of inflammation risk of dental implants. However, this behavior has to be confirmed by subsequent studies in vivo.$$leng 000462429 591__ $$aGermany 000462429 650_7 $$2SWD$$aBiomaterial 000462429 650_7 $$2SWD$$aWärmeausdehnung 000462429 650_7 $$2SWD$$aZahnimplantat 000462429 653_7 $$aBioaktives Glas 000462429 653_7 $$aIngenieurwissenschaften 000462429 653_7 $$abioactive glass 000462429 653_7 $$adental implant 000462429 653_7 $$athermal expansion 000462429 7001_ $$0P:(DE-82)IDM03582$$aFischer, Horst$$b1$$eThesis advisor$$urwth 000462429 7001_ $$0P:(DE-82)IDM00473$$aTelle, Rainer$$b2$$eThesis advisor 000462429 8564_ $$uhttps://publications.rwth-aachen.de/record/462429/files/5277.pdf$$yOpenAccess 000462429 8564_ $$uhttps://publications.rwth-aachen.de/record/462429/files/5277_source.docx$$yrestricted 000462429 8564_ $$uhttps://publications.rwth-aachen.de/record/462429/files/5277.gif?subformat=icon$$xicon$$yOpenAccess 000462429 8564_ $$uhttps://publications.rwth-aachen.de/record/462429/files/5277.jpg?subformat=icon-180$$xicon-180$$yOpenAccess 000462429 8564_ $$uhttps://publications.rwth-aachen.de/record/462429/files/5277.jpg?subformat=icon-700$$xicon-700$$yOpenAccess 000462429 8564_ $$uhttps://publications.rwth-aachen.de/record/462429/files/5277.pdf?subformat=pdfa$$xpdfa$$yOpenAccess 000462429 909CO $$ooai:publications.rwth-aachen.de:462429$$pVDB$$pdriver$$purn$$popen_access$$popenaire$$pdnbdelivery 000462429 9141_ $$y2015 000462429 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess 000462429 9201_ $$0I:(DE-82)542000-3_20140620$$k542000-3$$lLehr- und Forschungsgebiet Zahnärztliche Werkstoffkunde und Biomaterialforschung$$x0 000462429 9201_ $$0I:(DE-82)524110_20140620$$k524110$$lLehrstuhl für Keramik und feuerfeste Werkstoffe und Institut für Gesteinshüttenkunde$$x1 000462429 9201_ $$0I:(DE-82)520000_20140620$$k520000$$lFachgruppe für Materialwissenschaft und Werkstofftechnik$$x2 000462429 970__ $$aHT018549562 000462429 9801_ $$aFullTexts 000462429 980__ $$aConvertedRecord 000462429 980__ $$aI:(DE-82)520000_20140620 000462429 980__ $$aI:(DE-82)524110_20140620 000462429 980__ $$aI:(DE-82)542000-3_20140620 000462429 980__ $$aUNRESTRICTED 000462429 980__ $$aVDB 000462429 980__ $$aphd