000463827 001__ 463827 000463827 005__ 20250613102910.0 000463827 020__ $$a978-3-89336-997-3 000463827 0247_ $$2URN$$aurn:nbn:de:hbz:82-opus-52511 000463827 0247_ $$2OPUS$$a5251 000463827 0247_ $$2Laufende Nummer$$a34337 000463827 0247_ $$2HBZ$$aHT018566480 000463827 0247_ $$2ISSN$$a1866-1807 000463827 037__ $$aRWTH-CONV-145413 000463827 041__ $$aGerman 000463827 082__ $$a530 000463827 1001_ $$0P:(DE-82)463828$$aBlab, Marcus$$b0 000463827 245__ $$aLadungstransportmessungen an Si(111)-Oberflächen mit einem Multispitzen-Rastertunnelmikroskop$$cMarcus Blab$$honline, print 000463827 246_3 $$aCharge transport measurements at Si(111) surfaces with a multitip scanning tunneling microscope$$yEnglish 000463827 260__ $$aJülich$$bForschungszentrum Jülich$$c2014 000463827 260__ $$c2015 000463827 300__ $$a114 S. : Ill., graph. Darst. 000463827 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd 000463827 3367_ $$02$$2EndNote$$aThesis 000463827 3367_ $$2DRIVER$$adoctoralThesis 000463827 3367_ $$2BibTeX$$aPHDTHESIS 000463827 3367_ $$2DataCite$$aOutput Types/Dissertation 000463827 3367_ $$2ORCID$$aDISSERTATION 000463827 3367_ $$0PUB:(DE-HGF)3$$2PUB:(DE-HGF)$$aBook$$mbook 000463827 4900_ $$aSchriften des Forschungszentrums Jülich : Reihe Schlüsseltechnologien$$v93 000463827 500__ $$aDruckausgabe: 2014. - Onlineausgabe: 2015. Auch veröffentlicht auf dem Publikationsserver der RWTH Aachen University 000463827 502__ $$aZugl.: Aachen, Techn. Hochsch., Diss., 2014$$bDiss.$$cAachen, Techn. Hochsch.$$d2014$$gFak01$$o2014-09-22 000463827 5203_ $$aDiese Arbeit befasst sich mit der Charakterisierung und Weiterentwicklung eines Multispitzen - Rastertunnelmikroskops, mit dessen Hilfe die elektrische Leitfähigkeit verschiedener Silizium (Si) Oberflächen gemessen wurden. Multispitzen - Rastertunnelmikroskope werden unter anderem zur Bestimmung der elektrischen Leitfähigkeit von Nanostrukturen genutzt. Um den Einfluss von Kontaktwiderstände zu vermeiden wird mit Hilfe der Vierpunktmethode der Widerstand der Probe gemessen, weshalb das hier verwendete Rastertunnelmikroskop vier Spitzen besitzt. Abbildungen der Platin (Pt)(100) Oberfläche an Luft zeigen die rekonstruierte Oberfläche, atomare Stufenkanten und eine Drift von 1,6 Å/min nach 18 Stunden. Die Entwicklung eines neuen Nanopositionierers, dem KoalaDrive, zur Annäherung der Spitzen an die Probe, machte es möglich das Multispitzen-Rastertunnelmikroskop sehr kompakt zu halten. Hierfür musste ein Aufbau des KoalaDrives gefunden werden, welcher auch zuverlässig im Vakuum funktioniert. Nach der erfolgreichen Charakterisierung und Weiterentwicklung des Multispitzen-Rastertunnelmikroskops werden Ladungstransportmessungen an verschiedenen Si(111) Oberflächen durchgeführt und die Ergebnisse diskutiert. Die Leitfähigkeit der bismutterminierten Si(111) Oberfläche ist mit der Leitfähigkeit von Bismut mit einer Dicke von 3Å zu vergleichen. Die spezifische Leitfähigkeit beträgt (0, 16 ± 0, 07) mS/. Die Si(111)-7×7 Oberfläche hat eine spezifische Leitfähigkeit von (4, 0 ± 0, 1) μS/ und leitet somit nur 40 mal schlechter als die bismutterminierte Siliziumoberfläche. Zusätzlich wird gezeigt, dass die Si(111)-7×7 Oberfläche elektrisch nahezu völlig vom Siliziumvolumen entkoppelt ist und daher der Strom fast ausschließlich durch die Oberfläche fließt. Abschließend wird mit Hilfe eines chemischen Verfahrens die Oberfläche wasserstoffterminiert, sodass auch die spezifische Volumenleitfähigkeit einer Si(111) Probe gemessen werden konnte. Für eine geplante Weiterentwicklung des Multispitzen-Rastertunnelmikroskops in ein Multispitzen-Rasterkraftmikroskop wird zunächst die Funktionalität eines Needlesensors als Kraftdetektor überprüft. Dieser Sensor ist im Vergleich zu anderen Sensoren sehr kompakt und wäre durch seine Geometrie optimal für Multispitzen-Rasterkraftmikroskope geeignet. Zur Positionierung der vier Spitzen in einem Punkt müssen die Sensoren in einem Winkel von 45° zur Oberfläche angebracht werden. Es wird gezeigt, dass das Abbilden der Oberfläche deutlich schwieriger ist als das Abbilden mit einem Sensor, der senkrecht zur Oberfläche steht. Mögliche Ursachen hierfür sind „Snap to contact” und Eigenfrequenzen der Spitze, die im Bereich der Eigenfrequenz des Needlesensors liegen.$$lger 000463827 520__ $$aThis work concernes with the characterization and further development of a multitip scanning tunneling microscope and charge transport measurements on several silicon (Si)(111) surfaces. Multitip-scanning tunneling microscopes are used among others to determine the electrical conductance of nanostructures. To get rid of the contact resistance, the four-point method is used to measure the resistance of the sample. Therefore four individual tips were used to make up the multitip scanning tunneling microscope. Images of the platin (Pt)(100) surface under ambient conditions show a reconstructed surface, atomic steps and a drift of 1.6 Å/min after 18 hours. The development of a new nanopositioner, the KoalaDrive, to approach the tip to the sample, made the new multitip scanning tunneling microsope ultra compact. However a setup of the KoalaDrive, which works reliably in vacuum, had to be found. After a successful characterization and further development of the multitip scanning tunneling microscope, charge transport measurements on several Si(111) surfaces were realised. The conductance of the bismuthterminated Si(111) surface is comparable with a 3Å thick bismuth layer. The conductivity of the bismuthterminated Si(111) surface is (0.16 ± 0.07) mS/. The conductivity of the Si(111)-7×7 surface is (4.0±0.1) μS/ and therefore only 40 times smaller than the conductivity of the bismuthterminated silicon surface. Additionally it will be shown that the Si(111)-7×7 surface is electrically strong decoupled from the bulk and the main part of the current flows through the surface. Furthermore the Si(111) surface will be hydrogen passivated by using a chemical procedure. In doing this the surface states were removed so that the bulk conductance of the silicon sample could be measured. For a planned development of a multitip scanning tunneling microscope in a multitip atomic force microscopes the functionality of a needle-sensor as a force detector will be varified. In comparison to other sensors, the needle-sensor is very compact and due to its geometry it would be optimal for multitip atomic force microscopes. For positioning of all four tips of the multitip atomic force microscope at one location, the sensors have to be attached at an angle of 45° with respect to the surface. It becomes apparent that the imaging of surfaces is more complicated than using a sensor which is perpendicularly mounted to the surface. ”Snap to contact” and eigenfrequencies of the tip which are close to the eigenfrequency of the sensor could be a possible explanation.$$leng 000463827 591__ $$aGermany 000463827 650_7 $$2SWD$$aLadungstransport 000463827 650_7 $$2SWD$$aSilicium 000463827 650_7 $$2SWD$$aOberflächenphysik 000463827 650_7 $$2SWD$$aRastertunnelmikroskop 000463827 653_7 $$aPhysik 000463827 653_7 $$aMultispitzen-Rastertunnelmikroskop 000463827 653_7 $$aSilizium 000463827 653_7 $$amultitip scanning tunneling micoscope 000463827 7001_ $$0P:(DE-82)006430$$aVoigtländer, Bert$$b1$$eThesis advisor 000463827 7001_ $$0P:(DE-82)IDM00029$$aMorgenstern, Markus$$b2$$eThesis advisor 000463827 8564_ $$uhttps://publications.rwth-aachen.de/record/463827/files/5251.pdf 000463827 8564_ $$uhttps://publications.rwth-aachen.de/record/463827/files/5251.gif?subformat=icon$$xicon 000463827 8564_ $$uhttps://publications.rwth-aachen.de/record/463827/files/5251.jpg?subformat=icon-180$$xicon-180 000463827 8564_ $$uhttps://publications.rwth-aachen.de/record/463827/files/5251.jpg?subformat=icon-700$$xicon-700 000463827 909CO $$ooai:publications.rwth-aachen.de:463827$$pdnbdelivery$$popenaire$$popen_access$$purn$$pdriver$$pVDB 000463827 9141_ $$y2014 000463827 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess 000463827 9201_ $$0I:(DE-82)134110_20140620$$k134110$$lLehrstuhl für Experimentalphysik IV A (FZ Jülich)$$x0 000463827 9201_ $$0I:(DE-82)130000_20140620$$k130000$$lFachgruppe Physik$$x1 000463827 961__ $$z2015-02-27 000463827 970__ $$aHT018566480 000463827 9801_ $$aFullTexts 000463827 980__ $$aphd 000463827 980__ $$aVDB 000463827 980__ $$aUNRESTRICTED 000463827 980__ $$aI:(DE-82)134110_20140620 000463827 980__ $$aI:(DE-82)130000_20140620 000463827 980__ $$aConvertedRecord 000463827 980__ $$abook