000056542 001__ 56542 000056542 005__ 20220422215833.0 000056542 0247_ $$2URN$$aurn:nbn:de:hbz:82-opus-1577 000056542 0247_ $$2HBZ$$aHT013113178 000056542 0247_ $$2OPUS$$a157 000056542 0247_ $$2Laufende Nummer$$a23439 000056542 037__ $$aRWTH-CONV-118636 000056542 041__ $$aGerman 000056542 082__ $$a610 000056542 1001_ $$0P:(DE-82)050668$$aHermanns, Elvira Maria$$b0$$eAuthor 000056542 245__ $$aDDD- und VDD-Schrittmacher-Therapie: Einfluß der oberen Grenzfrequenz auf die kardiale Leistungsfähigkeit$$cvorgelegt von Elvira Maria Hermanns$$honline, print 000056542 260__ $$aAachen$$bPublikationsserver der RWTH Aachen University$$c2001 000056542 300__ $$aIV, 106 S. : graph. Darst. 000056542 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd 000056542 3367_ $$02$$2EndNote$$aThesis 000056542 3367_ $$2DRIVER$$adoctoralThesis 000056542 3367_ $$2BibTeX$$aPHDTHESIS 000056542 3367_ $$2DataCite$$aOutput Types/Dissertation 000056542 3367_ $$2ORCID$$aDISSERTATION 000056542 502__ $$aAachen, Techn. Hochsch., Diss., 2001$$gFak10$$o2001-02-09 000056542 5203_ $$aDie Variation der Herzfrequenz stellt die wichtigste Determinante der Herzminutenvolumenadaption unter Belastung dar. Daher wurde bei 20 Patienten mit einem aufgrund eines höhergradigen AV-Blocks implantierten Zweikammerschrittmacher (16 VDD-Systeme, 4 DDD-Systeme) der Einfluß der oberen Grenzfrequenz auf die kardiopulmonale Belastbarkeit untersucht. Mittels Spiroergometrie wurde bei randomisiert programmierten oberen Grenzfrequenzen (OGF) von 110, 120 oder 130/min die Sauerstoffaufnahme (VO2) an der anaeroben Schwelle (AT) und an der Ausbelastungsgrenze bestimmt. Elf Patienten (60 ± 6J.) ohne relevante Herzinsuffizienz (Weber A/B) profitierten signifikant von einer OGF von 130/min gegenüber einer OGF 110/min (VO2-AT 17,3 ± 3,9ml/min/kg vs 13,7 ± 4,0ml/min/kg, p<0,001). Neun Patienten (71 ± 12J.) mit relevanter Herzinsuffizienz (Weber C/D) erreichten dagegen eine höhere Belastbarkeit bei einer OGF von 110/min gegenüber einer OGF von 130/min (VO2-AT 11,1 ± 4,0ml/min/kg vs 9,2 ± 2,6ml/min/kg, p=0,052). Transthorakale echokardiographische Untersuchungen zeigten unter Ruhebedingungen bei den verschiedenen OGF keine Unterschiede hinsichtlich der Ejektionsfraktion bei Patienten mit und ohne Herzinsuffizienz. Durch klinische Einstufung der Patienten anhand der NYHA-Klassifikation konnte die kardiale Belastbarkeit bei den einzelnen OGF nicht valide beurteilt werden. Bei Patienten mit Zweikammerschrittmachern ist der kardiopulmonale Belastungstest also ein geeignetes Verfahren zur Optimierung der OGF. Bei Patienten ohne Herzinsuffizienz sollte eine höhere OGF programmiert werden, während bei Patienten mit Herzinsuffizienz die OGF auf niedrige Werte begrenzt werden sollte.$$lger 000056542 520__ $$aThe variation of heart rate is the most significant factor of cardiac output during exercise conditions. The influence of the upper tracking rate on cardiac performance was investigated at a sample of twenty patients having a dual chamber pacemaker implanted for high degree AV block. At randomly programmed upper tracking rates (UPR) of 110, 120 or 130bpm oxygen uptake was determined at the anaerobic threshold and at peak exercise using the cardiopulmonary exercise test. Eleven patients (60 ± 6 years) without severe heart failure (Weber A/B) showed a significant benefit of an UPR of 130bpm in contrast to 110bpm (VO2-AT 17,3 ± 3,9ml/min/kg vs 13,7 ± 4,0ml/min/kg, p<0,001). For nine patients (71 ± 12 years) with severe heart failure the cardiac performance was higher at an UPR of 110bpm vs 130bpm (VO2-AT 11,1 ± 4,0ml/min/kg vs 9,2 ± 2,6ml/min/kg, p=0,052). Two-dimensional echocardiography at rest did not reveal any differences of ejection fraction between patients with or without heart failure at various UPR. Cardiac performance at different UPR could not exactly be evaluated using the heart failure classification by the NYHA. For patients with dual chamber acemakers the upper tracking rate can be optimised by the cardiopulmonary exercise test. Higher UPR should be set for patients without heart failure, whereas the UPR should be limited to lower values for patients with heart failure.$$leng 000056542 591__ $$aGermany 000056542 653_7 $$aMedizin 000056542 7001_ $$0P:(DE-82)025378$$aSigmund, Martin$$b1$$eThesis advisor 000056542 8564_ $$uhttps://publications.rwth-aachen.de/record/56542/files/Hermanns_Elvira.pdf 000056542 8564_ $$uhttps://publications.rwth-aachen.de/record/56542/files/56542_kardex.pdf$$yInternal catalog entry 000056542 8564_ $$uhttps://publications.rwth-aachen.de/record/56542/files/56542_kardex.gif?subformat=icon$$xicon$$yInternal catalog entry 000056542 8564_ $$uhttps://publications.rwth-aachen.de/record/56542/files/56542_kardex.jpg?subformat=icon-180$$xicon-180$$yInternal catalog entry 000056542 8564_ $$uhttps://publications.rwth-aachen.de/record/56542/files/56542_kardex.jpg?subformat=icon-700$$xicon-700$$yInternal catalog entry 000056542 909CO $$ooai:publications.rwth-aachen.de:56542$$pVDB$$pdriver$$purn$$popen_access$$popenaire$$pdnbdelivery 000056542 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess 000056542 9201_ $$0I:(DE-82)510000-1_20140620$$k510000-1$$lMedizinische Fakultät$$x0 000056542 961__ $$c2014-06-16$$x2007-07-17$$z2012-02-20 000056542 970__ $$aHT013113178 000056542 980__ $$aphd 000056542 980__ $$aI:(DE-82)510000-1_20140620 000056542 980__ $$aVDB 000056542 980__ $$aUNRESTRICTED 000056542 980__ $$aConvertedRecord 000056542 9801_ $$aFullTexts 000056542 980__ $$aFullTexts