h1

h2

h3

h4

h5
h6
000661803 001__ 661803
000661803 005__ 20230408004853.0
000661803 0247_ $$2URN$$aurn:nbn:de:hbz:82-rwth-2016-059741
000661803 0247_ $$2HBZ$$aHT019078094
000661803 0247_ $$2Laufende Nummer$$a35422
000661803 037__ $$aRWTH-2016-05974
000661803 041__ $$aGerman
000661803 082__ $$a620
000661803 1001_ $$0P:(DE-82)186496$$aHöfner, Tobias$$b0
000661803 245__ $$aEntwicklung von Membran-Elektroden-Einheiten für die Anionenaustauschmembran-Wasserelektrolyse$$cvorgelegt von Tobias Höfner$$honline
000661803 246_3 $$aDevelopment of membrane electrode assemblies for the anion exchange membrane water electrolysis$$yEnglish
000661803 260__ $$aAachen$$c2016
000661803 300__ $$a1 Online-Ressource (II, 136 Seiten) : Illustrationen, Diagramme
000661803 3367_ $$2DataCite$$aOutput Types/Dissertation
000661803 3367_ $$2ORCID$$aDISSERTATION
000661803 3367_ $$2BibTeX$$aPHDTHESIS
000661803 3367_ $$02$$2EndNote$$aThesis
000661803 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd
000661803 3367_ $$2DRIVER$$adoctoralThesis
000661803 502__ $$aDissertation, Rheinisch-Westfälische Technische Hochschule Aachen, 2016$$bDissertation$$cRheinisch-Westfälische Technische Hochschule Aachen$$d2016$$gFak04$$o2016-05-24
000661803 500__ $$aVeröffentlicht auf dem Publikationsserver der RWTH Aachen University
000661803 5203_ $$aDurch den Einsatz von Anionenaustauschmembranen in Polymerelektrolytmembran- Wasserelektrolyseuren sollen die Vorteile der alkalischen- und der Polymerelektrolyt- membran-Wasserelektrolyse kombiniert und gleichzeitig deren Nachteile eliminiert werden.In der Anionenaustauschmembran-Wasserelektrolyse verwendete Ionomere tragen in den polymeren Seitenketten in der Regel quatäre Amine. Entsprechende Ionomere erreichen im Wasserelektrolysebetrieb zwar ausreichend hohe ionische Leitfähigkeiten. Die an der Kathode gebildeten Hydroxidanionen zerstören jedoch die funktionellen Gruppen der Ionomere. In der Folge sinkt die ionische Leitfähigkeit und somit die Wasserstoffproduktionsrate des Elektrolyseurs. Gegenstand dieser Arbeit ist ein Materialscreening von kommerziellen und präkom- merziellen Anionenaustauschmembranen, Ionomerlösungen und Elektrokatalysatoren. Die am besten geeigneten Materialien werden für die Entwicklung von Membran- Elektroden-Einheiten ausgewählt und im Elektrolysebetrieb charakterisiert. Durch eine gezielte Auswahl der Anionenaustauschmembranen und Ionomerlösungen sowie durch eine Optimierung der Betriebsparameter soll der Abbau der funktionellen Gruppen der Ionomere im Betrieb reduziert werden. Im Einsatz in der Anionenaustauschmembran- Wasserelektrolyse sollen die entwickelten Membran-Elektroden-Einheiten eine möglichst hohe Stromdichte aufweisen. Zudem sollen in den Elektrodenschichten ausschließlich edelmetallfreie Katalysatoren eingesetzt werden. Auf Basis aktuell am Markt verfügbarer Anionenaustauschmembranen, Elektrokatalysa- toren und Ionomerlösungen lassen sich Membran-Elektroden-Einheiten herstellen, die im Elektrolysebetrieb maximal eine Stromdichte von 1,4 A/cm2 bei 2,1 V und 50 °C erreichen. Die im Rahmen dieser Arbeit entwickelten Membran-Elektroden-Einheiten enthielten ausschließlich nickelbasierte Elektrokatalysatoren und erreichten eine Betriebsdauer von 300 h mit einer Alterungsrate von 0,7 mV/h. Durch die Kontrolle der Ionenaustausch- kapazität, konnte gezeigt werden, dass vor allem das in den Elektrodenschichten verwendete Ionomer für diese stark begrenzte Lebensdauer verantwortlich ist.$$lger
000661803 520__ $$aThe use of an anion exchange membrane as an electrolyte allows to combine the benefits of the alkaline- and the polymer electrolyte membrane water electrolysis and simultaneously eliminates their limitations. The ionomers used in this so called anion exchange membrane water electrolysis usually contain quaternary amines as functional groups. These kind of ionomers provide a sufficiently high ionic conductivity for the elctrolysis operation. Hydroxide anions that are formed at the cathode however destroy those functional groups causing a subsequent loss in ionic conductivity and thus reduce the hydrogen production rate of the electrolyser. The aim of this work is a material screening of commercial and pre-commercial anion exchange membranes, ionomers and electro catalysts. The most suitable materials are chosen for the development of membrane electrode assemblies and characterised during water electrolysis operation. By selecting the membranes and ionomers and by optimizing the operational parameters, the chemical degradation of the functional groups of the ionomers is to be reduced. During water electrolysis operation, the membrane electrode assemblies should show the highest possible current densities. Furthermore, the electrode layers are designed without the use of precious metal catalysts. Based on anion exchange membranes, ionomers and electro catalysts that are available on the market to date, it is possible to build membrane electrode assemblies that reach a current density of 1.4 A/cm2 at 2.1 V and 50 °C during electrolysis operation. The membrane electrode assemblies developed in this study only contained nickel-based electro catalysts and reached an operational lifetime of 300 h at a performance degradation of 0.7 mV/h. By observing the ion-exchange-capacity, it was demonstrated that particularly the ionomer used in the electrode layer is responsible for this severely limited lifetime.$$leng
000661803 591__ $$aGermany
000661803 653_7 $$awater electrolysis
000661803 653_7 $$aanion exchange membrane
000661803 7001_ $$0P:(DE-82)IDM01238$$aStolten, Detlef$$b1$$eThesis advisor
000661803 7001_ $$0P:(DE-82)IDM00066$$aPich, Andrij$$b2$$eThesis advisor$$urwth
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803.pdf$$yOpenAccess
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803_source.doc$$yRestricted
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803_source.docx$$yRestricted
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803_source.odt$$yRestricted
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803_source.pdf$$yRestricted
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803.gif?subformat=icon$$xicon$$yOpenAccess
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803.jpg?subformat=icon-700$$xicon-700$$yOpenAccess
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803_source.gif?subformat=icon$$xicon$$yRestricted
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803_source.jpg?subformat=icon-1440$$xicon-1440$$yRestricted
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803_source.jpg?subformat=icon-180$$xicon-180$$yRestricted
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803_source.jpg?subformat=icon-640$$xicon-640$$yRestricted
000661803 8564_ $$uhttps://publications.rwth-aachen.de/record/661803/files/661803_source.jpg?subformat=icon-700$$xicon-700$$yRestricted
000661803 909CO $$ooai:publications.rwth-aachen.de:661803$$pdnbdelivery$$pVDB$$pdriver$$purn$$popen_access$$popenaire
000661803 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000661803 9141_ $$y2016
000661803 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00066$$aRWTH Aachen$$b2$$kRWTH
000661803 9201_ $$0I:(DE-82)413010_20140620$$k413010$$lLehrstuhl für Brennstoffzellen (FZ Jülich)$$x0
000661803 961__ $$c2016-11-17T17:53:43.534953$$x2016-08-08T20:28:55.826495$$z2016-11-17T17:53:43.534953
000661803 9801_ $$aFullTexts
000661803 980__ $$aphd
000661803 980__ $$aVDB
000661803 980__ $$aI:(DE-82)413010_20140620
000661803 980__ $$aUNRESTRICTED