000681013 1001_ $$0P:(DE-82)021434$$aLinde, Torsten$$b0
000681013 245__ $$aExperimentelle und numerische Evaluierung thrombosegefährdeter Bereiche in Herzklappenprothesen$$cTorsten Linde$$honline, print
000681013 246_3 $$aExperimental and numerical evaluation of thrombogenic locations in heart valve prostheses$$yEnglish
000681013 260__ $$aAachen$$bShaker Verlag$$c2016
000681013 260__ $$c2017
000681013 300__ $$a1 Online-Ressource (VIII, 219 Seiten) : Illustrationen, Diagramme
000681013 3367_ $$2DataCite$$aOutput Types/Dissertation
000681013 3367_ $$0PUB:(DE-HGF)3$$2PUB:(DE-HGF)$$aBook$$mbook
000681013 3367_ $$2ORCID$$aDISSERTATION
000681013 3367_ $$2BibTeX$$aPHDTHESIS
000681013 3367_ $$02$$2EndNote$$aThesis
000681013 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd
000681013 3367_ $$2DRIVER$$adoctoralThesis
000681013 4900_ $$aAachener Beiträge zur Medizintechnik$$v40
000681013 500__ $$aDruckausgabe: 2016. - Auch veröffentlicht auf dem Publikationsserver der RWTH Aachen University 2017
000681013 502__ $$aDissertation, RWTH Aachen University, 2016$$bDissertation$$cRWTH Aachen University$$d2016$$gFak04$$o2016-04-08
000681013 5203_ $$aDie Thrombosierung von medizinischen Implantaten, insbesondere von Herzklappenprothesen, stellt trotz medikamentöser Therapie die häufigste auf das Implantat zurückzuführende Komplikation dar. Speziell die Ursachen strömungsinduzierter Thrombose sind immer noch nicht gut verstanden, sodass keine effektiven Methoden zur Beurteilung zur Verfügung stehen. Eine Möglichkeit kann die gezielte experimentelle und numerische Evaluierung der lokalen, strömungsinduzierten Thromboseneigung von Herzklappenprothesen und deren Korrelation bieten.Da für die experimentelle Evaluierung keine adäquate Methode zur Verfügung steht, wurde ein geeigneter Kreislaufsimulator für Herzklappen (THIA3) und eine Methodik für die In-vitro-Untersuchung initialer Thrombosierung entwickelt und validiert. Die Methodik erlaubte eine reproduzierbare Thrombosierung der getesteten Prothesen nach vier Stunden. Die Validität konnte über den Vergleich mit Tierversuchen und Literaturdaten gezeigt werden.Für die Korrelation thrombogener Strömungen wurden numerische Simulationen an zwei Herzklappenprothesen, die Triflo Dreiflügelprothese und die St. Jude Medical Zweiflügelprothese, in Aortenposition unter Berücksichtigung dynamischer Randbedingungen in Fluent (ANSYS) durchgeführt und mittels Particle Image Velocimetry (PIV) validiert. Die hydrodynamischen Randbedingungen und die Klappenbewegung wurden aus Experimenten im THIA3 abgeleitet. Hinsichtlich der Thrombogenität konnte für beide Klappen eine gute Korrelation für zwei Strömungsformen hergestellt werden.Die Untersuchungen zeigten, dass die Methode eine gute Möglichkeit der Evaluierung der lokalen Thromboseneigung in Herzklappen ist und wichtige Informationen für das Design neuentwickelter Klappenprothesen liefert.$$lger
000681013 520__ $$aDispite medical therapies thrombogenic complications are one of the most common reasons for implant failure, especially for heart valve prostheses. Reasons for thrombogenicity are not very well understood, especially if flow induced. There are no reliable and effective methods available to evaluate different design variations towards their thrombogenic effect. Good option would be the combination of numerical an experimental methods and their correlation to directly evaluate the effect of local flow distribution towards their thrombogenicity.Since there is no applicable method available for the experimental evaluation a special mock circulation loop for heart valves (the THIA3) was designed and validated comparing the results with literature and animal trials. All relevant physiological an pathological conditions could be simulated in the tester. Reproducible results for local thrombogenicity were possible within four hours test duration.Computational fluid dynamic (CFD) simulations were carried out in Fluent 13 (ANSYS) for two heart valve prostheses in aortic position – the Triflo trileaflet (Triflo Inc.) and the St. Jude Medical bileaflet valve – under concideration of the dynamic boundary conditions. Hydrodynamic conditions and valve motion were gathered from the experimental set up. The simulations were validated using Particle Image Velocimetry (PIV) in the THIA3.Comparison of flow field distribution inside the valves and initial clot formation at the valves showed good correlation for two flow patterns for both of the valves.This method showed the ability to evaluate thrombogenic performance of heart valve prostheses and to gather important information for necessary design changes in newly developed valves.$$leng
000681013 591__ $$aGermany
000681013 653_7 $$aheart valves
000681013 653_7 $$athrombosis
000681013 653_7 $$ablood
000681013 653_7 $$ain vitro testing
000681013 653_7 $$aCFD
000681013 653_7 $$aPIV
000681013 7001_ $$0P:(DE-82)000567$$aSteinseifer, Ulrich$$b1$$eThesis advisor
000681013 7001_ $$0P:(DE-82)IDM00681$$aSchröder, Wolfgang$$b2$$eThesis advisor$$urwth
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013.pdf$$yOpenAccess
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013_source.doc$$yRestricted
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013_source.docx$$yRestricted
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013_source.odt$$yRestricted
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013_source.pdf$$yRestricted
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013.gif?subformat=icon$$xicon$$yOpenAccess
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013.jpg?subformat=icon-700$$xicon-700$$yOpenAccess
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013_source.gif?subformat=icon$$xicon$$yRestricted
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013_source.jpg?subformat=icon-180$$xicon-180$$yRestricted
000681013 8564_ $$uhttps://publications.rwth-aachen.de/record/681013/files/681013_source.jpg?subformat=icon-700$$xicon-700$$yRestricted
000681013 909CO $$ooai:publications.rwth-aachen.de:681013$$pdnbdelivery$$pVDB$$pdriver$$purn$$popen_access$$popenaire
000681013 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000681013 9141_ $$y2016
000681013 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00681$$aRWTH Aachen$$b2$$kRWTH
000681013 9201_ $$0I:(DE-82)811001-4_20140620$$k811001-4$$lLehr- und Forschungsgebiet Kardiovaskuläre Technik$$x0
000681013 9201_ $$0I:(DE-82)415110_20140620$$k415110$$lLehrstuhl für Strömungslehre und Aerodynamisches Institut$$x1
000681013 961__ $$c2017-03-01T20:06:50.023403$$x2016-12-28T17:03:47.833123$$z2017-03-01T20:06:50.023403
000681013 9801_ $$aFullTexts
000681013 980__ $$aphd
000681013 980__ $$aVDB
000681013 980__ $$abook
000681013 980__ $$aI:(DE-82)811001-4_20140620
000681013 980__ $$aI:(DE-82)415110_20140620
000681013 980__ $$aUNRESTRICTED