h1

h2

h3

h4

h5
h6
000689803 001__ 689803
000689803 005__ 20230408005201.0
000689803 0247_ $$2datacite_doi$$a10.18154/RWTH-2017-04595
000689803 0247_ $$2Laufende Nummer$$a36132
000689803 0247_ $$2HBZ$$aHT019369055
000689803 037__ $$aRWTH-2017-04595
000689803 041__ $$aEnglish
000689803 082__ $$a620
000689803 1001_ $$0P:(DE-82)692189$$aTiddens, Arne$$b0
000689803 245__ $$aMeasurement methods for investigating the air return ratio of open volumetric receivers at solar power towers$$cvorgelegt von Arne Tidde Tiddens$$honline
000689803 246_3 $$aMessverfahren zur Untersuchung der Luftrückführrate an offenen volumetrischen Receivern von Solarturmanlagen$$yGerman
000689803 260__ $$aAachen$$c2017
000689803 300__ $$a1 Online-Ressource (VI, 130 Seiten) : Illustrationen, Diagrammme
000689803 3367_ $$2DataCite$$aOutput Types/Dissertation
000689803 3367_ $$2ORCID$$aDISSERTATION
000689803 3367_ $$2BibTeX$$aPHDTHESIS
000689803 3367_ $$02$$2EndNote$$aThesis
000689803 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd
000689803 3367_ $$2DRIVER$$adoctoralThesis
000689803 502__ $$aDissertation, RWTH Aachen University, 2017$$bDissertation$$cRWTH Aachen University$$d2017$$gFak04$$o2017-05-05
000689803 500__ $$aVeröffentlicht auf dem Publikationsserver der RWTH Aachen University
000689803 5203_ $$aKostenreduzierung spielt bei der konzentrierenden Solarthermie eine maßgebliche Rolle. Daher ist es essentiell, alle Faktoren, die den Systemwirkungsgrad einer Solarturmanlage beeinflussen, zu quantifizieren. Die Luftrückführrate ist ein Schlüsselfaktor des offenen volumetrischen Solarreceivers, welche das Verhältnis von zurückgeführter Luft zu eingesaugter Luft beschreibt. Um einen hohen Receiverwirkungsgrad zu erreichen, ist es wichtig, die Luftrückführrate zu erhöhen. Viele Parameter, wie z. B. die Windgeschwindigkeit und -richtung, die Geometrie des Receivers sowie die Betriebsweise, haben einen Einfluss auf die Strömung vor dem Receiver und somit auch auf die Luftrückführrate. Daher ist es essentiell, die Luftrückführrate messtechnisch zu quantifizierenund die Strömung vor dem Receiver zu visualisieren. Bislang wurde dies weder auf einem industriellem Maßstab noch unter dem Einfluss von konzentrierter Solarstrahlung umgesetzt.Die Entwicklung eines Messverfahrens zur Quantifizierung der Luftrückführrate mit möglichst hoher Präzision stellt den Kern dieser Arbeit dar. Weiterhin wurde erstmalig die Rückführluft vor dem Receiver visualisiert. Diese erlaubt ein besseres Verständnis der auftretenden Strömungsphänomene, welche maßgeblich die Luftrückführung bestimmen. Messverfahren, die dies ermöglichen, wurden in dieser Arbeit im Labormaßstab entwickelt, unter Betriebsbedingungen erprobt und erfolgreich am Solarturm Jülich angewandt.Um die Luftrückführrate quantitativ zu bestimmen, wurden drei Varianten eines neuartigen, zirkulären Indikatorgasverfahren entwickelt. Das Indikatorgas wurde hierbei entweder kontinuierlich oder intermittierend dem offenen Luftkreislauf hinzugefügt und über die unvollständige Luftrückführung verdünnt. Der Stoffmengenanteil des zugeführten Edelgases Helium wurde mittels eines Massenspektrometers im Luftkreislauf bestimmt und daraus die Luftrückführrate berechnet. Eine zeitliche Auflösung von 0.5 s wurde erreicht. Eine maximale Luftrückführrate von (68.6 ± 0.7)% mit 95% Konfidenzintervall wurde unter Bestrahlung mit konzentrierter Solarstrahlung am Versuchskraftwerk Jülich gemessen. Dieser Wert ist höher als die bisher angenommene Luftrückführrate von 60%. Dieser Unterschied in der Luftrückführrate entspricht einem 4−5% höherem Gesamtsystemwirkungsgrad. Die Visualisierung der Rückführluft wurde erstmalig mit einer zu diesem Zweck entwickelten Induzierten Infrarot Thermographie erzielt. Hierbei wurde die Rückführluft mit Kohlenstoffdioxid angereichert und somit eine erhöhte Strahlung im infraroten Wellenlängenbereich induziert. Die von der Rückführluft abgegebenen Strahlung konnte mittels einer Infrarotkamera visualisiert werden.$$lger
000689803 520__ $$aCost reduction plays a significant role in the field of concentrated solar thermal energy. It is therefore essential to quantify all factors that influence the energy conversion efficiency. The air return ratio is a key factor for the overall efficiency of the open volumetric receiver. It is the fraction of the blown out air which is sucked in again through the solar receiver. To achieve a high receiver efficiency it is therefore important to increase the air return ratio. Many variables such as wind speed and direction, geometry of the receiver design and operational mode influence the air flow in front of the receiver. This in turn influences the air return ratio. It is therefore of vital importance to be able to measure the air return ratio and furthermore visualize the air flow in front of the receiver. The air return value was prior to this work unknown on a large scale and under concentrated solar irradiation.The development of a measurement technique for the quantification of the air return ratio with maximum accuracy is the main objective of this thesis. The second objective lies in the visualization of the returned air. This improves the understanding of the occurring flow phenomena which govern the air return ratio. The measurement methods were developed at a lab scale, tested under operating conditions and successfully demonstrated at the solar tower Jülich. In order to measure the air return ratio, three variants of a novel circular tracer gas measurement technique have been developed. The tracer gas is injected either continuously or intermittently into the open air system. The tracer gas is diluted by the imperfect air return ratio. The mole fraction of the injected noble gas helium is measured with a mass spectrometer within the air system, from which the air return ratio is determined. A temporal resolution of 0.5 s has been achieved. A maximal air return ratio of (68.6 ± 0.7)% with 95% confidence interval has been measured during irradiation with concentrated sunlight at the solar tower power plant Jülich. This is higher than thepreviously assumed air return ratio of 60%. This difference corresponds to a 4 − 5% higher overall system efficiency. The return air in front of the receiver was visualized for the first time with the newly developed Induced Infrared Thermography. Hereby, carbon dioxide is added to the return air. This induces a larger amount of radiationbeing given off in the infrared region. This radiation from the return air is visualized using an infrared camera.$$leng
000689803 588__ $$aDataset connected to Lobid/HBZ
000689803 591__ $$aGermany
000689803 653_7 $$aair return ratio
000689803 653_7 $$atracer gas
000689803 653_7 $$asolar tower Jülich
000689803 653_7 $$asolar air receiver
000689803 653_7 $$aair receiver
000689803 653_7 $$ameasurement technique
000689803 653_7 $$adynamic mass spectroscopy
000689803 653_7 $$aflow visualization
000689803 653_7 $$ainduced infrared thermography
000689803 653_7 $$aIIT
000689803 653_7 $$ainfrared image velocimetry
000689803 653_7 $$aIRIV
000689803 7001_ $$0P:(DE-82)020408$$aHoffschmidt, Bernhard$$b1$$eThesis advisor$$urwth
000689803 7001_ $$0P:(DE-82)140921$$aKemna, Andreas$$b2$$eThesis advisor
000689803 8564_ $$uhttps://publications.rwth-aachen.de/record/689803/files/689803.pdf$$yOpenAccess
000689803 8564_ $$uhttps://publications.rwth-aachen.de/record/689803/files/689803_source.zip$$yRestricted
000689803 8564_ $$uhttps://publications.rwth-aachen.de/record/689803/files/689803.gif?subformat=icon$$xicon$$yOpenAccess
000689803 8564_ $$uhttps://publications.rwth-aachen.de/record/689803/files/689803.jpg?subformat=icon-1440$$xicon-1440$$yOpenAccess
000689803 8564_ $$uhttps://publications.rwth-aachen.de/record/689803/files/689803.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000689803 8564_ $$uhttps://publications.rwth-aachen.de/record/689803/files/689803.jpg?subformat=icon-640$$xicon-640$$yOpenAccess
000689803 8564_ $$uhttps://publications.rwth-aachen.de/record/689803/files/689803.jpg?subformat=icon-700$$xicon-700$$yOpenAccess
000689803 8564_ $$uhttps://publications.rwth-aachen.de/record/689803/files/689803.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000689803 909CO $$ooai:publications.rwth-aachen.de:689803$$popenaire$$popen_access$$pVDB$$pdriver$$pdnbdelivery
000689803 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000689803 9141_ $$y2017
000689803 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-HGF)0$$aRWTH Aachen$$b0$$kRWTH
000689803 9201_ $$0I:(DE-82)421010_20140620$$k421010$$lLehrstuhl für Solare Komponenten (DLR)$$x0
000689803 961__ $$c2017-07-07T08:32:11.223360$$x2017-05-22T11:59:40.826670$$z2017-07-07T08:32:11.223360
000689803 9801_ $$aFullTexts
000689803 980__ $$aphd
000689803 980__ $$aVDB
000689803 980__ $$aI:(DE-82)421010_20140620
000689803 980__ $$aUNRESTRICTED