h1

h2

h3

h4

h5
h6
000748558 001__ 748558
000748558 005__ 20230408005733.0
000748558 0247_ $$2HBZ$$aHT019854494
000748558 0247_ $$2Laufende Nummer$$a37631
000748558 0247_ $$2datacite_doi$$a10.18154/RWTH-2018-229484
000748558 037__ $$aRWTH-2018-229484
000748558 041__ $$aEnglish
000748558 082__ $$a621.3
000748558 1001_ $$0P:(DE-588)1170602851$$aSlim, Jamal$$b0$$urwth
000748558 245__ $$aA novel waveguide RF Wien filter for electric dipole moment measurements of deuterons and protons at the COoler SYnchrotron (COSY)/Jülich$$cvorgelegt von Master of Science Jamal S. Slim$$honline
000748558 260__ $$aAachen$$c2018
000748558 300__ $$a1 Online-Ressource (VIII, 150 Seiten : Illustrationen
000748558 3367_ $$02$$2EndNote$$aThesis
000748558 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd
000748558 3367_ $$2BibTeX$$aPHDTHESIS
000748558 3367_ $$2DRIVER$$adoctoralThesis
000748558 3367_ $$2DataCite$$aOutput Types/Dissertation
000748558 3367_ $$2ORCID$$aDISSERTATION
000748558 500__ $$aVeröffentlicht auf dem Publikationsserver der RWTH Aachen University. - Ausgezeichnet mit der Borchers-Plakette und dem Friedrich-Wilhelm-Preis 2019.
000748558 502__ $$aDissertation, Rheinisch-Westfälische Technische Hochschule Aachen, 2018$$bDissertation$$cRheinisch-Westfälische Technische Hochschule Aachen$$d2018$$gFak06$$o2018-10-18
000748558 5203_ $$aDie Materie-Antimaterie Asymmetrie im Universum lässt sich nicht durch bekannte Quellen der CP Verletzung im Standard Modell (SM) erklären. Nicht-verschwindende elektrische Dipolmomente (EDM) fundamentaler Teilchen verletzen sowohl die Zeitumkehrinvarianz (T) als auch die Parität (P), und sind daher, CPT Erhaltung vorausgesetzt, ebenfalls CP verletzend. Die Suche nach EDMs geladener Teilchen erfordert die Entwicklung eines dedizierten elektrischen Speicherrings, jedoch steht gegenwärtig ein solches Gerät noch nicht zur Verfügung. Aus diesem Grund hat die JEDI Kollaboration (Jülich Electric Dipole moment Investigations) damit begonnen, den existierenden magnetischen Speicherring COSY (COoler SYnchrotron) mit einem neuartigen RF Wien filter auszustatten. Mit diesem Gerät kann die weltweit erste direkte Messung des elektrischen Dipolmoments des Protons und des Deuterons durchgeführt werden. In Verbindung mit COSY erzeugt der RF Wien Filter ein Signal, das proportional zum EDM ist. Die vorliegende Arbeit beschäftigt sich mit dem Design, mit Simulationen und Analyse, sowie der Realisierung und der Inbetriebnahme des RF Wien Filters. ähnlich wie im klassischen Wien Filter, stellt der RF Wien Filter ein elektromagnetisches Gerät dar, welches orthogonale Felder mit einem klar definierten Verhältnis zwischen elektrischem und magnetischem Feld erzeugt. Unter idealen Bedingungen verschwindet die Lorentzkraft, und dann erzeugt der RF Wien Filter keinen transversalen Stahlversatz. Der RF Wien Filter operiert auf einer Harmonischen der Spinpräzessionsfrequenz, und dadurch kommt es zu einer Akkumulation des EDM Signals als Funktion der Zeit. Feldinhomogenitäten führen jedoch zur falschen EDM Signalen, und deshalb wurde der RF Wien Filter auf der Basis eines Wellenleiters entwickelt. Um das Gerät zu entwickeln und zu optimieren, wurden Vollwellensimulationen der vollständigen mechanischen Struktur des RF Wien Filters durchgeführt. Die Lorentzkraft verschwindet nahezu vollständig und es wurden sehr hohe Feldhomogenitäten erreicht. Eine Analyse der mechanischen Toleranzen und Fehlstellungen wurde ebenfalls durchgeführt. Der RF Treiberkreis funktioniert gut und erfüllt die an ihn gestellten Anforderungen. Er erlaubt die Anpassung der RF Amplitude und Phase des Feldquotienten. Das Gerät wurde erfolgreich mit gespeichertem Protonenstrahl an COSY in Betrieb genommen. Durch Fehlübereinstimmung der Impendanz wurde der gespeicherte Strahl angeregt Strahl, und Amplituden der Oszillationen des Strahls zwischen 0 und 25 µm konnten nachgewiesen werden.$$lger
000748558 520__ $$aThe matter-antimatter asymmetry in the universe cannot be explained by the level of predicted CP-violation sources in the Standard Model (SM) of particles. As a possible explanation, is the existence of permanent electric dipole moment (EDM) as a fundamental property of particles. The search for EDM of charged particles requires a dedicated all-electric storage ring, an option that is not available at the moment. Therefore, the JEDI (Jülich Electric Dipole moment Investigations) collaboration has decided to equip the existing magnetic storage ring, the COoler SYnchrotron (COSY), with a novel device called the radio frequency (RF) Wien filter to conduct the first ever EDM measurement of deuterons and protons. The RF Wien filter is a device, that is able of generating an EDM signal proportional to the spin precession of particles. This thesis is concerned with the design, simulation, analysis, realization and commissioning of the RF Wien filter. Similar to the classical Wien filter, the RF Wien filter is an electromagnetic device that generates orthogonal fields with a well-defined ratio between the electric and magnetic field. These conditions lead to a vanishing Lorentz force, thus the device does/should not introduce any beam distortion. Secondly, it is a spin sensitive device; it operates at the resonant spin precession frequencies at which, the influence of the RF Wien filter on the particles' spin is maximized. Moreover, high field homogeneity is sought as inhomogeneities lead to a fake EDM signal. These requirements are found to be met by the waveguide based RF Wien filter. Full-wave simulations have been conducted to design and optimize the full-structure including the mechanical parts. Nearly vanishing Lorentz force with high field homogeneities have been achieved. Analysis of mechanical tolerances and misalignments have been included in the calculations. The RF driving circuit worked well and fulfilled its requirements in terms of adapting the magnitude and phase of the field quotient. The device has been successfully commissioned with proton beam measurements. With excited impedance mismatch, it was possible to drive beam oscillations from 0 up to 25 µm.$$leng
000748558 588__ $$aDataset connected to Lobid/HBZ
000748558 591__ $$aGermany
000748558 653_7 $$aComputational electromagnetics
000748558 653_7 $$aElectric Dipole Moment
000748558 653_7 $$aElectromagnetic Fields
000748558 653_7 $$aElectromagnetic Simulation
000748558 653_7 $$aLorentz Force
000748558 653_7 $$aPolynomial Chaos Expansion
000748558 653_7 $$aRF Circuit
000748558 653_7 $$aStochastic Galerkin Method
000748558 653_7 $$aWaveguide RF Wien Filter
000748558 7001_ $$0P:(DE-82)IDM00418$$aHeberling, Dirk$$b1$$eThesis advisor$$urwth
000748558 7001_ $$0P:(DE-82)IDM00596$$aHameyer, Kay$$b2$$eThesis advisor$$urwth
000748558 7001_ $$0P:(DE-82)IDM01239$$aPretz, Jörg Johannes$$b3$$eThesis advisor$$urwth
000748558 8564_ $$uhttps://publications.rwth-aachen.de/record/748558/files/748558.pdf$$yOpenAccess
000748558 8564_ $$uhttps://publications.rwth-aachen.de/record/748558/files/748558_source.zip$$yRestricted
000748558 8564_ $$uhttps://publications.rwth-aachen.de/record/748558/files/748558.gif?subformat=icon$$xicon$$yOpenAccess
000748558 8564_ $$uhttps://publications.rwth-aachen.de/record/748558/files/748558.jpg?subformat=icon-1440$$xicon-1440$$yOpenAccess
000748558 8564_ $$uhttps://publications.rwth-aachen.de/record/748558/files/748558.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000748558 8564_ $$uhttps://publications.rwth-aachen.de/record/748558/files/748558.jpg?subformat=icon-640$$xicon-640$$yOpenAccess
000748558 8564_ $$uhttps://publications.rwth-aachen.de/record/748558/files/748558.jpg?subformat=icon-700$$xicon-700$$yOpenAccess
000748558 8564_ $$uhttps://publications.rwth-aachen.de/record/748558/files/748558.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000748558 909CO $$ooai:publications.rwth-aachen.de:748558$$popenaire$$popen_access$$pVDB$$pdriver$$pdnbdelivery
000748558 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-588)1170602851$$aRWTH Aachen$$b0$$kRWTH
000748558 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00418$$aRWTH Aachen$$b1$$kRWTH
000748558 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00596$$aRWTH Aachen$$b2$$kRWTH
000748558 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM01239$$aRWTH Aachen$$b3$$kRWTH
000748558 9141_ $$y2018
000748558 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000748558 9201_ $$0I:(DE-82)613110_20140620$$k613110$$lLehrstuhl und Institut für Hochfrequenztechnik$$x0
000748558 961__ $$c2018-12-06T14:48:32.795136$$x2018-10-26T14:11:19.790164$$z2018-12-06T14:48:32.795136
000748558 9801_ $$aFullTexts
000748558 980__ $$aI:(DE-82)613110_20140620
000748558 980__ $$aUNRESTRICTED
000748558 980__ $$aVDB
000748558 980__ $$aphd