000760168 001__ 760168 000760168 005__ 20230408005934.0 000760168 020__ $$a978-3-8325-4906-0 000760168 0247_ $$2HBZ$$aHT020044579 000760168 0247_ $$2Laufende Nummer$$a38107 000760168 0247_ $$2datacite_doi$$a10.18154/RWTH-2019-04006 000760168 037__ $$aRWTH-2019-04006 000760168 041__ $$aEnglish 000760168 082__ $$a621.3 000760168 1001_ $$0P:(DE-82)IDM01812$$aRichter, Jan-Gerrit$$b0$$urwth 000760168 245__ $$aFast measurement of individual head-related transfer functions$$cJan-Gerrit Richter$$honline, print 000760168 260__ $$aBerlin$$bLogos Verlag Berlin GmbH$$c2019 000760168 300__ $$a1 Online-Ressource (III, 151 Seiten) : Illustrationen, Diagramme 000760168 3367_ $$02$$2EndNote$$aThesis 000760168 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd 000760168 3367_ $$0PUB:(DE-HGF)3$$2PUB:(DE-HGF)$$aBook$$mbook 000760168 3367_ $$2BibTeX$$aPHDTHESIS 000760168 3367_ $$2DRIVER$$adoctoralThesis 000760168 3367_ $$2DataCite$$aOutput Types/Dissertation 000760168 3367_ $$2ORCID$$aDISSERTATION 000760168 4900_ $$aAachener Beiträge zur Akustik$$v30 000760168 500__ $$aVeröffentlicht auf dem Publikationsserver der RWTH Aachen University 000760168 502__ $$aDissertation, RWTH Aachen University, 2019$$bDissertation$$cRWTH Aachen University$$d2019$$gFak06$$o2019-02-22 000760168 5203_ $$aWährend Anwendungen binauraler Technologie in den letzten Jahren an Popularität gewonnen haben, verwenden die meisten Anwendungen immer noch nicht-individuelle kopfbezogene Übertragungsfunktionen (HRTFs) von Kunstköpfen. Diese Datensätze ermöglichen eine relativ gute räumliche Lokalisierung, die besonders gut funktioniert, wenn ein zusätzlicher visueller Hinweis verwendet wird. Bestimmte Anwendungen, wie z.B. die Erforschung des räumlichen Hörens oder der auditiven Aufmerksamkeit, erfordern jedoch ein physikalisch genaues und realistisches binaurales Signal. Darüber hinaus wurde in vielen Experimenten gezeigt, dass durch den Einsatz individueller HRTFs, z.B. bei Lokalisierungsaufgaben, ein erheblicher Nutzen entsteht. Der limitierende Faktor, der die weit verbreitete Nutzung individueller HRTFs verbietet, ist die Erfassung solcher Daten. Eine erhebliche Hardwareanforderung behindert eine universellere Nutzung. Selbst für Institutionen, welche individuelle Messungen durchführen können, machte die erforderliche Messzeit in der die Probanden bewegungslos verbleiben müssen, die meisten Messungen in der Vergangenheit unmöglich. Dieser Zeitbedarf wurde kürzlich durch die Parallelisierung des Messsignals reduziert, was zur Entwicklung schneller Messsysteme führte, welche in der Lage sind, individuelle und räumlich hochaufgelöste HRTFs zu erfassen. Diese Arbeit stellt eine objektive und subjektive Bewertung eines solchen Systems vor, das mit dem Ziel entwickelt wurde die Messungen in einem möglichst geringen Ausmaß zu stören. Eine detaillierte Untersuchung der zusätzlichen Verzerrung des Schallfeldes durch das System selbst wird vorgestellt. Zusätzlich wird gezeigt, dass das System in Bezug auf die Lokalisierung der Schallquellen mit einem herkömmlichen Messsystem vergleichbar ist. Darüber hinaus wird ein Verfahren eingeführt und ausgewertet, welches die Messzeit durch kontinuierliche Rotation während der Messung weiter verkürzt. Mit dieser Methode wird die Messdauer von acht Minuten auf drei Minuten ohne hörbare Unterschiede reduziert. Die vorgestellten Methoden werden auch verwendet, um zusätzliche Fehler durch die Bewegung des Subjekts zu reduzieren. Es wird gezeigt, dass diese Bewegung durch ein visuelles Feedback-System auf ein Niveau reduziert werden kann, das effizient kompensiert werden kann.$$lger 000760168 520__ $$aWhile binaural technology applications gained in popularity in recent years, the majority of applications still use non-individual Head-Related Transfer Functions (HRTFs) from artificial heads. These datasets enable a reasonably good spatial localization which works especially well when using an additional visual cue. However, certain applications, for example research of spatial hearing or hearing attention, require an physically exact and realistic binaural signal. Moreover, it was shown in many experiments that there is a substantial gain from the use of individual HRTFs, for example in localization tasks. The limiting factor that prohibits the widespread use of individual HRTFs is the acquisition of such data. A substantial hardware requirement obstructs a more universal usage. Even for institutions that allow individual measurements, the measurement time that is required, and that the subjects are required to remain motionless made most measurements unfeasible in the past. This time requirement has recently been reduced by the use of parallelization in the measurement signal which lead to the development of fast measurement systems capable of acquiring individual and spatially dense HRTF. This thesis provides a objective and subjective evaluation of such a system that is designed with the goal of little disturbance of the measurements in mind. The construction is detailed, followed by both an objective and subjective evaluation. A detailed investigation into additional distortion of the sound field introduced by the system itself is presented and it is shown that the system performs comparably to a conventional system in terms of sound source localization. Furthermore, a method is introduced and evaluated to further reduce the measurement time by using continuous rotation during the measurement. This method is used to reduced the measurement duration from eight minutes to three minutes without audible differences. The introduced methods are also used to reducing additional errors from subject movement. It is shown that this movement can be reduced by a visual feedback system to a level that can be compensated efficiently.$$leng 000760168 588__ $$aDataset connected to Lobid/HBZ 000760168 591__ $$aGermany 000760168 653_7 $$aAkustik 000760168 653_7 $$aBinaural Technik 000760168 653_7 $$aHRTFs 000760168 653_7 $$aMesstechnik 000760168 7001_ $$0P:(DE-82)IDM00134$$aFels, Janina$$b1$$eThesis advisor$$urwth 000760168 7001_ $$0P:(DE-82)IDM01628$$aJax, Peter Johannes$$b2$$eThesis advisor$$urwth 000760168 8564_ $$uhttps://publications.rwth-aachen.de/record/760168/files/760168.pdf$$yOpenAccess 000760168 8564_ $$uhttps://publications.rwth-aachen.de/record/760168/files/760168_source.zip$$yRestricted 000760168 8564_ $$uhttps://publications.rwth-aachen.de/record/760168/files/760168.gif?subformat=icon$$xicon$$yOpenAccess 000760168 8564_ $$uhttps://publications.rwth-aachen.de/record/760168/files/760168.jpg?subformat=icon-1440$$xicon-1440$$yOpenAccess 000760168 8564_ $$uhttps://publications.rwth-aachen.de/record/760168/files/760168.jpg?subformat=icon-180$$xicon-180$$yOpenAccess 000760168 8564_ $$uhttps://publications.rwth-aachen.de/record/760168/files/760168.jpg?subformat=icon-640$$xicon-640$$yOpenAccess 000760168 8564_ $$uhttps://publications.rwth-aachen.de/record/760168/files/760168.jpg?subformat=icon-700$$xicon-700$$yOpenAccess 000760168 909CO $$ooai:publications.rwth-aachen.de:760168$$pVDB$$pdnbdelivery$$pdriver$$popen_access$$popenaire 000760168 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM01812$$aRWTH Aachen$$b0$$kRWTH 000760168 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00134$$aRWTH Aachen$$b1$$kRWTH 000760168 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM01628$$aRWTH Aachen$$b2$$kRWTH 000760168 9141_ $$y2019 000760168 915__ $$0LIC:(DE-HGF)CCBYNCND4$$2HGFVOC$$aCreative Commons Attribution-NonCommercial-NoDerivs CC BY-NC-ND 4.0 000760168 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess 000760168 9201_ $$0I:(DE-82)613620_20160720$$k613620$$lLehr- und Forschungsgebiet für Medizinische Akustik$$x0 000760168 961__ $$c2019-05-08T14:25:26.456908$$x2019-04-26T15:57:30.374319$$z2019-05-08T14:25:26.456908 000760168 9801_ $$aFullTexts 000760168 980__ $$aI:(DE-82)613620_20160720 000760168 980__ $$aUNRESTRICTED 000760168 980__ $$aVDB 000760168 980__ $$abook 000760168 980__ $$aphd