h1

h2

h3

h4

h5
h6


001     760168
005     20230408005934.0
020 _ _ |a 978-3-8325-4906-0
024 7 _ |2 HBZ
|a HT020044579
024 7 _ |2 Laufende Nummer
|a 38107
024 7 _ |2 datacite_doi
|a 10.18154/RWTH-2019-04006
037 _ _ |a RWTH-2019-04006
041 _ _ |a English
082 _ _ |a 621.3
100 1 _ |0 P:(DE-82)IDM01812
|a Richter, Jan-Gerrit
|b 0
|u rwth
245 _ _ |a Fast measurement of individual head-related transfer functions
|c Jan-Gerrit Richter
|h online, print
260 _ _ |a Berlin
|b Logos Verlag Berlin GmbH
|c 2019
300 _ _ |a 1 Online-Ressource (III, 151 Seiten) : Illustrationen, Diagramme
336 7 _ |0 2
|2 EndNote
|a Thesis
336 7 _ |0 PUB:(DE-HGF)11
|2 PUB:(DE-HGF)
|a Dissertation / PhD Thesis
|b phd
|m phd
336 7 _ |0 PUB:(DE-HGF)3
|2 PUB:(DE-HGF)
|a Book
|m book
336 7 _ |2 BibTeX
|a PHDTHESIS
336 7 _ |2 DRIVER
|a doctoralThesis
336 7 _ |2 DataCite
|a Output Types/Dissertation
336 7 _ |2 ORCID
|a DISSERTATION
490 0 _ |a Aachener Beiträge zur Akustik
|v 30
500 _ _ |a Veröffentlicht auf dem Publikationsserver der RWTH Aachen University
502 _ _ |a Dissertation, RWTH Aachen University, 2019
|b Dissertation
|c RWTH Aachen University
|d 2019
|g Fak06
|o 2019-02-22
520 3 _ |a Während Anwendungen binauraler Technologie in den letzten Jahren an Popularität gewonnen haben, verwenden die meisten Anwendungen immer noch nicht-individuelle kopfbezogene Übertragungsfunktionen (HRTFs) von Kunstköpfen. Diese Datensätze ermöglichen eine relativ gute räumliche Lokalisierung, die besonders gut funktioniert, wenn ein zusätzlicher visueller Hinweis verwendet wird. Bestimmte Anwendungen, wie z.B. die Erforschung des räumlichen Hörens oder der auditiven Aufmerksamkeit, erfordern jedoch ein physikalisch genaues und realistisches binaurales Signal. Darüber hinaus wurde in vielen Experimenten gezeigt, dass durch den Einsatz individueller HRTFs, z.B. bei Lokalisierungsaufgaben, ein erheblicher Nutzen entsteht. Der limitierende Faktor, der die weit verbreitete Nutzung individueller HRTFs verbietet, ist die Erfassung solcher Daten. Eine erhebliche Hardwareanforderung behindert eine universellere Nutzung. Selbst für Institutionen, welche individuelle Messungen durchführen können, machte die erforderliche Messzeit in der die Probanden bewegungslos verbleiben müssen, die meisten Messungen in der Vergangenheit unmöglich. Dieser Zeitbedarf wurde kürzlich durch die Parallelisierung des Messsignals reduziert, was zur Entwicklung schneller Messsysteme führte, welche in der Lage sind, individuelle und räumlich hochaufgelöste HRTFs zu erfassen. Diese Arbeit stellt eine objektive und subjektive Bewertung eines solchen Systems vor, das mit dem Ziel entwickelt wurde die Messungen in einem möglichst geringen Ausmaß zu stören. Eine detaillierte Untersuchung der zusätzlichen Verzerrung des Schallfeldes durch das System selbst wird vorgestellt. Zusätzlich wird gezeigt, dass das System in Bezug auf die Lokalisierung der Schallquellen mit einem herkömmlichen Messsystem vergleichbar ist. Darüber hinaus wird ein Verfahren eingeführt und ausgewertet, welches die Messzeit durch kontinuierliche Rotation während der Messung weiter verkürzt. Mit dieser Methode wird die Messdauer von acht Minuten auf drei Minuten ohne hörbare Unterschiede reduziert. Die vorgestellten Methoden werden auch verwendet, um zusätzliche Fehler durch die Bewegung des Subjekts zu reduzieren. Es wird gezeigt, dass diese Bewegung durch ein visuelles Feedback-System auf ein Niveau reduziert werden kann, das effizient kompensiert werden kann.
|l ger
520 _ _ |a While binaural technology applications gained in popularity in recent years, the majority of applications still use non-individual Head-Related Transfer Functions (HRTFs) from artificial heads. These datasets enable a reasonably good spatial localization which works especially well when using an additional visual cue. However, certain applications, for example research of spatial hearing or hearing attention, require an physically exact and realistic binaural signal. Moreover, it was shown in many experiments that there is a substantial gain from the use of individual HRTFs, for example in localization tasks. The limiting factor that prohibits the widespread use of individual HRTFs is the acquisition of such data. A substantial hardware requirement obstructs a more universal usage. Even for institutions that allow individual measurements, the measurement time that is required, and that the subjects are required to remain motionless made most measurements unfeasible in the past. This time requirement has recently been reduced by the use of parallelization in the measurement signal which lead to the development of fast measurement systems capable of acquiring individual and spatially dense HRTF. This thesis provides a objective and subjective evaluation of such a system that is designed with the goal of little disturbance of the measurements in mind. The construction is detailed, followed by both an objective and subjective evaluation. A detailed investigation into additional distortion of the sound field introduced by the system itself is presented and it is shown that the system performs comparably to a conventional system in terms of sound source localization. Furthermore, a method is introduced and evaluated to further reduce the measurement time by using continuous rotation during the measurement. This method is used to reduced the measurement duration from eight minutes to three minutes without audible differences. The introduced methods are also used to reducing additional errors from subject movement. It is shown that this movement can be reduced by a visual feedback system to a level that can be compensated efficiently.
|l eng
588 _ _ |a Dataset connected to Lobid/HBZ
591 _ _ |a Germany
653 _ 7 |a Akustik
653 _ 7 |a Binaural Technik
653 _ 7 |a HRTFs
653 _ 7 |a Messtechnik
700 1 _ |0 P:(DE-82)IDM00134
|a Fels, Janina
|b 1
|e Thesis advisor
|u rwth
700 1 _ |0 P:(DE-82)IDM01628
|a Jax, Peter Johannes
|b 2
|e Thesis advisor
|u rwth
856 4 _ |u https://publications.rwth-aachen.de/record/760168/files/760168.pdf
|y OpenAccess
856 4 _ |u https://publications.rwth-aachen.de/record/760168/files/760168_source.zip
|y Restricted
856 4 _ |u https://publications.rwth-aachen.de/record/760168/files/760168.gif?subformat=icon
|x icon
|y OpenAccess
856 4 _ |u https://publications.rwth-aachen.de/record/760168/files/760168.jpg?subformat=icon-1440
|x icon-1440
|y OpenAccess
856 4 _ |u https://publications.rwth-aachen.de/record/760168/files/760168.jpg?subformat=icon-180
|x icon-180
|y OpenAccess
856 4 _ |u https://publications.rwth-aachen.de/record/760168/files/760168.jpg?subformat=icon-640
|x icon-640
|y OpenAccess
856 4 _ |u https://publications.rwth-aachen.de/record/760168/files/760168.jpg?subformat=icon-700
|x icon-700
|y OpenAccess
909 C O |o oai:publications.rwth-aachen.de:760168
|p openaire
|p open_access
|p driver
|p dnbdelivery
|p VDB
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-82)IDM01812
|a RWTH Aachen
|b 0
|k RWTH
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-82)IDM00134
|a RWTH Aachen
|b 1
|k RWTH
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-82)IDM01628
|a RWTH Aachen
|b 2
|k RWTH
914 1 _ |y 2019
915 _ _ |0 LIC:(DE-HGF)CCBYNCND4
|2 HGFVOC
|a Creative Commons Attribution-NonCommercial-NoDerivs CC BY-NC-ND 4.0
915 _ _ |0 StatID:(DE-HGF)0510
|2 StatID
|a OpenAccess
920 1 _ |0 I:(DE-82)613620_20160720
|k 613620
|l Lehr- und Forschungsgebiet für Medizinische Akustik
|x 0
980 1 _ |a FullTexts
980 _ _ |a I:(DE-82)613620_20160720
980 _ _ |a UNRESTRICTED
980 _ _ |a VDB
980 _ _ |a book
980 _ _ |a phd


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21