h1

h2

h3

h4

h5
h6
000762545 001__ 762545
000762545 005__ 20230408045955.0
000762545 0247_ $$2HBZ$$aHT020117424
000762545 0247_ $$2Laufende Nummer$$a38394
000762545 0247_ $$2datacite_doi$$a10.18154/RWTH-2019-05667
000762545 037__ $$aRWTH-2019-05667
000762545 041__ $$aEnglish
000762545 082__ $$a620
000762545 1001_ $$0P:(DE-588)1190124939$$abinti Azizan, Amizon$$b0$$urwth
000762545 245__ $$aOptical measurement and assessment of liquid distribution in shake flasks$$cvorgelegt von Amizon binti Azizan$$honline
000762545 246_3 $$aOptische Messung und Auswertung der Flüssigkeitsverteilung in Schüttelkolben$$yGerman
000762545 260__ $$aAachen$$c2018
000762545 260__ $$c2019
000762545 300__ $$a1 Online-Ressource (XIV, 192 Seiten) : Illustrationen, Diagramme
000762545 3367_ $$02$$2EndNote$$aThesis
000762545 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd
000762545 3367_ $$2BibTeX$$aPHDTHESIS
000762545 3367_ $$2DRIVER$$adoctoralThesis
000762545 3367_ $$2DataCite$$aOutput Types/Dissertation
000762545 3367_ $$2ORCID$$aDISSERTATION
000762545 500__ $$aVeröffentlicht auf dem Publikationsserver der RWTH Aachen University 2019
000762545 502__ $$aDissertation, Rheinisch-Westfälische Technische Hochschule, 2018$$bDissertation$$cRheinisch-Westfälische Technische Hochschule$$d2018$$gFak04$$o2018-12-20
000762545 5203_ $$aDie biotechnologische Entwicklung im Schüttelkolben erfordert wichtige Entwicklungsparameter, z.B. volumetrischer Leistungseintrag, Mischzeit, gas-flüssig Stoffübergangskoeffizient, hydromechanische Belastung und effektive Scherrate. Diese Arbeit liefert reichlich experimentelle Daten für zukünftige Validierungen, die Schüttelkolbenfluidströmungs-Hydrodynamik darstellen, das heißt In-Phase (IP) und Außer-Phase (AP) (Phasenphänomen). Das Phasenphänomen wurde früher auf der Grundlage des Leistungseintrags ausgedrückt und kann nun über die Flüssigkeitsverteilung ausgedrückt werden. Optische Fluoreszenz-Technik-Messung, die 7644 Datenkurven und 546 dreidimensionale (3D) Flüssigkeitsverteilungsdiagramme (hydrophil) ergab, resultierte aus der Analyse der Vorderkante der Bulk-Flüssigkeit (LB) und dem Schwanz der Bulk-Flüssigkeit (TB) bei einem Füllvolumen (VL) von 15-40 ml, einer Schüttelfrequenz (n) von 150-450 U/min, 0-120 g/L fluoreszierende Polyvinylpyrrolidonlösungen (Fluoreszenz-PVP) und einem Schütteldurchmesser von 25 mm. Die torusförmigen Formen von LB und TB sind eindeutig asymmetrisch, und der gemessene TB unterscheidet sich durch die Verlängerung der Flüssigkeit besonders zum Torusteil des Schüttelkolbens. Vier neue Bewertungskriterien, die aus 2184 ausgewerteten Fällen vorgeschlagen wurden, verdeutlichen, wie wir die 3D-Flüssigkeitsverteilung auf das Phasenphänomen beziehen. Die Bewertungskriterien für die gemessenen Daten sind die Filmdicke der rotierenden Bulk-Flüssigkeit, der relative Anstieg der LB-Kurven, der Kreiswinkel der LB-Positionen und der Peak-Form-Wandel der 3D-Bulk-Flüssigkeitsverteilung ($\geq$270$^\circ$ von 3D-Plot). Eine neue kompensierte kritische Phasennummer (Phcrit) von theoretischer zu gemessener IP und AP wird von 1,26 auf 0,91 überarbeitet. Somit tritt eine Phasenänderung des Flüssigkeitsstroms in einem 250-ml-Schüttelkolben bei 25 mm Schütteldurchmesser bei einem etwas höheren Viskositätsniveau der Fluoreszenz-PVP-Lösungen auf, als dies durch die theoretischen (berechneten) Phasenzahlwerte erwartet wird. Zusätzlich dazu wird das nicht-Viskositätsmodell, das als simulierte Daten dient, mit der untersuchten Flüssigkeitsverteilung verglichen, die einen Bereich von ähnlich zu variierender maximaler Flüssigkeitshöhe (Hmax) veranschaulicht. Der Einfluss von Hydrophobizität auf die Winkelposition der Flüssigkeitsverteilung verstärkt das Verlangen, die Film- und Bulk-Flüssigkeitsparameter weiter zu verstehen. Zusammenfassend sind die zahlreichen 3D-Flüssigkeitsverteilungsdaten, die bei unterschiedlichem Füllvolumina und Schüttelfrequenzen gesammelt wurden und LB- und TB-Werte in Bezug auf die Richtung der Zentrifugalbeschleunigung umfassen, für die Validierung zukünftiger numerischer Lösungen unter Verwendung von CFD erforderlich, um wichtige Ingenieurparameter im Schüttelkolben vorherzusagen.$$lger
000762545 520__ $$aBiotechnological development in shake flask necessitates vital engineering parameters e.g. volumetric power input, mixing time, gas-liquid mass transfer coefficient, hydromechanical stress and effective shear rate. This work provides ample experimental data for future validations representing shake flask fluid flow hydrodynamics i.e. in-phase (IP) and out-of-phase (OP) (phase phenomenon). Phase phenomenon was earlier expressed based on power input and that can now be expressed via liquid distribution. Optical fluorescence technique measurement producing 7644 data curves and 546 three-dimensional (3D) liquid distribution plots (hydrophilic), resulted from leading edge of bulk liquid (LB) and tail of bulk liquid (TB) analysis from 15-40 mL filling volume (VL), 150-450 rpm shaking frequency (n), 0-120 g/L of polyvinylpyrrolidone in fluorescent (fluorescent-PVP) solutions at 25 mm shaking diameter. The toroidal shapes of LB and TB are clearly asymmetrical and the measured TB differed by the elongation of the liquid particularly towards the torus part of the shake flask. Four new evaluation criteria proposed from 2184 evaluated cases, shed some light on how we closely relate 3D liquid distribution to phase phenomenon. The evaluation criteria on measured data are film thickness of the rotating bulk liquid, slope relative percentage of LB curves, circular angle of LB positions and 3D bulk liquid distribution’s peak shape change ($\geq$270$^\circ$ from 3D plot). A new compensated critical phase number (Phcrit) from theoretical to measured IP and OP has been revised from 1.26 to 0.91. Thus, phase change of liquid flow in 250-mL shake flask at 25 mm shaking diameter occurs at a little higher viscosity level of the fluorescent-PVP solutions than expected by the theoretical (calculated) phase number values. Additional to this, a non-viscosity model which serves as a simulated data is compared to measured liquid distribution investigated, illustrating range from similar to varying maximum liquid height (Hmax). Effect of hydrophobicity to liquid distribution angular position strengthen the fact to further understand the film and bulk liquid parameters. In conclusion, the 3D liquid distribution data collected at varying filling volume and shaking frequency, comprising of LB and TB values relative to the direction of the centrifugal acceleration are essential for validating future numerical solutions using CFD to predict vital engineering parameters in shake flask.$$leng
000762545 588__ $$aDataset connected to Lobid/HBZ
000762545 591__ $$aGermany
000762545 653_7 $$ain phase
000762545 653_7 $$aliquid distribution
000762545 653_7 $$aout of phase
000762545 653_7 $$ashake flask
000762545 7001_ $$0P:(DE-82)IDM00545$$aBüchs, Jochen$$b1$$eThesis advisor$$urwth
000762545 7001_ $$0P:(DE-82)710276$$aSpiess, Antje C.$$b2$$eThesis advisor$$urwth
000762545 8564_ $$uhttps://publications.rwth-aachen.de/record/762545/files/762545.pdf$$yOpenAccess
000762545 8564_ $$uhttps://publications.rwth-aachen.de/record/762545/files/762545_source.docx$$yRestricted
000762545 8564_ $$uhttps://publications.rwth-aachen.de/record/762545/files/762545.gif?subformat=icon$$xicon$$yOpenAccess
000762545 8564_ $$uhttps://publications.rwth-aachen.de/record/762545/files/762545.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000762545 8564_ $$uhttps://publications.rwth-aachen.de/record/762545/files/762545.jpg?subformat=icon-700$$xicon-700$$yOpenAccess
000762545 909CO $$ooai:publications.rwth-aachen.de:762545$$popenaire$$popen_access$$pVDB$$pdriver$$pdnbdelivery
000762545 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-588)1190124939$$aRWTH Aachen$$b0$$kRWTH
000762545 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00545$$aRWTH Aachen$$b1$$kRWTH
000762545 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)710276$$aRWTH Aachen$$b2$$kRWTH
000762545 9141_ $$y2018
000762545 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000762545 9201_ $$0I:(DE-82)416510_20140620$$k416510$$lLehrstuhl für Bioverfahrenstechnik$$x0
000762545 961__ $$c2019-08-13T09:19:00.698545$$x2019-06-13T07:38:42.168877$$z2019-08-13T09:19:00.698545
000762545 9801_ $$aFullTexts
000762545 980__ $$aI:(DE-82)416510_20140620
000762545 980__ $$aUNRESTRICTED
000762545 980__ $$aVDB
000762545 980__ $$aphd