h1

h2

h3

h4

h5
h6
000811228 001__ 811228
000811228 005__ 20260115135621.0
000811228 0247_ $$2HBZ$$aHT020873219
000811228 0247_ $$2Laufende Nummer$$a40068
000811228 0247_ $$2datacite_doi$$a10.18154/RWTH-2021-01042
000811228 037__ $$aRWTH-2021-01042
000811228 041__ $$aEnglish
000811228 082__ $$a620
000811228 1001_ $$0P:(DE-588)IDM01070$$aPeters, Lars Ingmar Eckart$$b0$$urwth
000811228 245__ $$aMembrane-based direct pH parametric pumping for protein concentration$$cvorgelegt von Lars Ingmar Eckart Peters$$honline
000811228 246_3 $$aMembran-basiertes direktes pH parametrisches Pumpen für Protein Aufreinigung und -konzentrierung$$yGerman
000811228 260__ $$aAachen$$bRWTH Aachen University$$c2020
000811228 260__ $$c2021
000811228 300__ $$a1 Online-Ressource : Illustrationen, Diagramme
000811228 3367_ $$02$$2EndNote$$aThesis
000811228 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd
000811228 3367_ $$0PUB:(DE-HGF)3$$2PUB:(DE-HGF)$$aBook$$mbook
000811228 3367_ $$2BibTeX$$aPHDTHESIS
000811228 3367_ $$2DRIVER$$adoctoralThesis
000811228 3367_ $$2DataCite$$aOutput Types/Dissertation
000811228 3367_ $$2ORCID$$aDISSERTATION
000811228 4900_ $$aAachener Verfahrenstechnik series - AVT.CVT - chemical process engineering$$v11 (2021)
000811228 500__ $$aVeröffentlicht auf dem Publikationsserver der RWTH Aachen University 2021
000811228 502__ $$aDissertation, Rheinisch-Westfälische Technische Hochschule Aachen, 2020$$bDissertation$$cRheinisch-Westfälische Technische Hochschule Aachen$$d2020$$gFak04$$o2020-10-21
000811228 5203_ $$aDie Aufreinigung und -konzentrierung von Proteinen aus Lösungen wird für industrielle Anwendungen von immer größerer Bedeutung. Klassicherweise werden diese mittels Festbettchromatographie durchgeführt. Membranprozesse, wie Membranchromatographie und Membranadsorber, haben für diese Anwendung in den letzten Jahren an Bedeutung gewonnen und in Spezialanwendungen ihre Wirksamkeit gezeigt. Vorteile von Membranprozessen liegen in kürzeren Diffusionswegen, schnelleren Bindungskinetiken, sowie einem geringeren Druckverlust. Membranprozesse sind hier jedoch meist auf Flachmembrananwendungen limitiert. Jedes dieser Verfahren erfordert eine aufwendige Vorfiltration der Lösung. Parametrische Pumpen-Prozesse mit einer Hohlfasermembran als stationärer Phase, anstelle von Festbetten, bieten die Möglichkeit die Vorfiltration zu verringern. Eingebettete Ionenaustauschpartikel in der Membranstruktur dienen als Ad- und Desorptionsfläche für das Protein, das seine Ladung dem pH-Wert der Lösung anpasst, sobald diese um den isoelektrischen Punkt des Proteins variert. Eine dichte Schicht auf der Außenseite der Membran verhindert den Durchbruch der Lösung und erlaubt ein blasenfreies zur pH-Kontrolle während des Prozesses. Experimentell wird die Kombination von parametrischem Pumpen und Membranprozessen gezeigt. Eine Prozesssimulation wird genutzt, um optimale Prozessbedingungen und -limitationen aufzuzeigen.$$lger
000811228 520__ $$aPurification and concentration of proteins from solutions gains ever more importance for industry. Typically, liquid packed chromatography is used in such processes. In recent years, membrane processes, such as membrane chromatography and membrane adsorbers, have challenged the state of the art processes. Membrane processes offer shorter diffusional pathways for the adsorption, faster binding kinetics and overall lower pressure drops, but are limited to a flat membrane geometry. Yet, any of these processes, to date, require extensive pre-filtration. Purification of an unfiltered protein broth is not feasible due to blocking or fouling of the internal membrane structure. Parametric pumping processes us- ing a hollow fiber membrane instead of a packed bed offer a potential pathway to overcome the need for an extensive prefiltration. Mixing ground ion exchange resins into the polymer solution prior to the phase inversion process enables the membrane to ad- and desorb proteins if the pH of the solution is alternated around the isoelectric point of the protein. A dense layer around the outside of the membrane prevents a liquid breakthrough and is used to control the pH by permeating pH shiftable gases. A experimental study is performed for the process and a process model is implemented to investigate further process conditions and to show the process limitation.$$leng
000811228 588__ $$aDataset connected to Lobid/HBZ
000811228 591__ $$aGermany
000811228 653_7 $$aFlüssiggaskontakter
000811228 653_7 $$aMembran
000811228 653_7 $$aProteinkonzentrierung
000811228 653_7 $$agas-liquid contactor
000811228 653_7 $$amembrane
000811228 653_7 $$aparametric pumping
000811228 653_7 $$aparametrische Pumpen
000811228 653_7 $$aprotein concentration
000811228 7001_ $$0P:(DE-82)IDM00476$$aWessling, Matthias$$b1$$eThesis advisor$$urwth
000811228 7001_ $$aEppink, Michel$$b2$$eThesis advisor
000811228 8564_ $$uhttps://publications.rwth-aachen.de/record/811228/files/811228.pdf$$yOpenAccess
000811228 8564_ $$uhttps://publications.rwth-aachen.de/record/811228/files/811228_source.zip$$yRestricted
000811228 909CO $$ooai:publications.rwth-aachen.de:811228$$popenaire$$popen_access$$pdriver$$pdnbdelivery$$pVDB
000811228 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-588)IDM01070$$aRWTH Aachen$$b0$$kRWTH
000811228 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM00476$$aRWTH Aachen$$b1$$kRWTH
000811228 9141_ $$y2020
000811228 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000811228 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000811228 9201_ $$0I:(DE-82)416110_20140620$$k416110$$lLehrstuhl für Chemische Verfahrenstechnik und Institut für Verfahrenstechnik$$x0
000811228 961__ $$c2021-03-23T16:20:54.274699$$x2021-01-25T20:11:08.735085$$z2021-03-23T16:20:54.274699
000811228 9801_ $$aFullTexts
000811228 980__ $$aI:(DE-82)416110_20140620
000811228 980__ $$aUNRESTRICTED
000811228 980__ $$aVDB
000811228 980__ $$abook
000811228 980__ $$aphd