h1

h2

h3

h4

h5
h6


001     811228
005     20260115135621.0
024 7 _ |2 HBZ
|a HT020873219
024 7 _ |2 Laufende Nummer
|a 40068
024 7 _ |2 datacite_doi
|a 10.18154/RWTH-2021-01042
037 _ _ |a RWTH-2021-01042
041 _ _ |a English
082 _ _ |a 620
100 1 _ |0 P:(DE-588)IDM01070
|a Peters, Lars Ingmar Eckart
|b 0
|u rwth
245 _ _ |a Membrane-based direct pH parametric pumping for protein concentration
|c vorgelegt von Lars Ingmar Eckart Peters
|h online
246 _ 3 |a Membran-basiertes direktes pH parametrisches Pumpen für Protein Aufreinigung und -konzentrierung
|y German
260 _ _ |a Aachen
|b RWTH Aachen University
|c 2020
260 _ _ |c 2021
300 _ _ |a 1 Online-Ressource : Illustrationen, Diagramme
336 7 _ |0 2
|2 EndNote
|a Thesis
336 7 _ |0 PUB:(DE-HGF)11
|2 PUB:(DE-HGF)
|a Dissertation / PhD Thesis
|b phd
|m phd
336 7 _ |0 PUB:(DE-HGF)3
|2 PUB:(DE-HGF)
|a Book
|m book
336 7 _ |2 BibTeX
|a PHDTHESIS
336 7 _ |2 DRIVER
|a doctoralThesis
336 7 _ |2 DataCite
|a Output Types/Dissertation
336 7 _ |2 ORCID
|a DISSERTATION
490 0 _ |a Aachener Verfahrenstechnik series - AVT.CVT - chemical process engineering
|v 11 (2021)
500 _ _ |a Veröffentlicht auf dem Publikationsserver der RWTH Aachen University 2021
502 _ _ |a Dissertation, Rheinisch-Westfälische Technische Hochschule Aachen, 2020
|b Dissertation
|c Rheinisch-Westfälische Technische Hochschule Aachen
|d 2020
|g Fak04
|o 2020-10-21
520 3 _ |a Die Aufreinigung und -konzentrierung von Proteinen aus Lösungen wird für industrielle Anwendungen von immer größerer Bedeutung. Klassicherweise werden diese mittels Festbettchromatographie durchgeführt. Membranprozesse, wie Membranchromatographie und Membranadsorber, haben für diese Anwendung in den letzten Jahren an Bedeutung gewonnen und in Spezialanwendungen ihre Wirksamkeit gezeigt. Vorteile von Membranprozessen liegen in kürzeren Diffusionswegen, schnelleren Bindungskinetiken, sowie einem geringeren Druckverlust. Membranprozesse sind hier jedoch meist auf Flachmembrananwendungen limitiert. Jedes dieser Verfahren erfordert eine aufwendige Vorfiltration der Lösung. Parametrische Pumpen-Prozesse mit einer Hohlfasermembran als stationärer Phase, anstelle von Festbetten, bieten die Möglichkeit die Vorfiltration zu verringern. Eingebettete Ionenaustauschpartikel in der Membranstruktur dienen als Ad- und Desorptionsfläche für das Protein, das seine Ladung dem pH-Wert der Lösung anpasst, sobald diese um den isoelektrischen Punkt des Proteins variert. Eine dichte Schicht auf der Außenseite der Membran verhindert den Durchbruch der Lösung und erlaubt ein blasenfreies zur pH-Kontrolle während des Prozesses. Experimentell wird die Kombination von parametrischem Pumpen und Membranprozessen gezeigt. Eine Prozesssimulation wird genutzt, um optimale Prozessbedingungen und -limitationen aufzuzeigen.
|l ger
520 _ _ |a Purification and concentration of proteins from solutions gains ever more importance for industry. Typically, liquid packed chromatography is used in such processes. In recent years, membrane processes, such as membrane chromatography and membrane adsorbers, have challenged the state of the art processes. Membrane processes offer shorter diffusional pathways for the adsorption, faster binding kinetics and overall lower pressure drops, but are limited to a flat membrane geometry. Yet, any of these processes, to date, require extensive pre-filtration. Purification of an unfiltered protein broth is not feasible due to blocking or fouling of the internal membrane structure. Parametric pumping processes us- ing a hollow fiber membrane instead of a packed bed offer a potential pathway to overcome the need for an extensive prefiltration. Mixing ground ion exchange resins into the polymer solution prior to the phase inversion process enables the membrane to ad- and desorb proteins if the pH of the solution is alternated around the isoelectric point of the protein. A dense layer around the outside of the membrane prevents a liquid breakthrough and is used to control the pH by permeating pH shiftable gases. A experimental study is performed for the process and a process model is implemented to investigate further process conditions and to show the process limitation.
|l eng
588 _ _ |a Dataset connected to Lobid/HBZ
591 _ _ |a Germany
653 _ 7 |a Flüssiggaskontakter
653 _ 7 |a Membran
653 _ 7 |a Proteinkonzentrierung
653 _ 7 |a gas-liquid contactor
653 _ 7 |a membrane
653 _ 7 |a parametric pumping
653 _ 7 |a parametrische Pumpen
653 _ 7 |a protein concentration
700 1 _ |0 P:(DE-82)IDM00476
|a Wessling, Matthias
|b 1
|e Thesis advisor
|u rwth
700 1 _ |a Eppink, Michel
|b 2
|e Thesis advisor
856 4 _ |u https://publications.rwth-aachen.de/record/811228/files/811228.pdf
|y OpenAccess
856 4 _ |u https://publications.rwth-aachen.de/record/811228/files/811228_source.zip
|y Restricted
909 C O |o oai:publications.rwth-aachen.de:811228
|p VDB
|p dnbdelivery
|p driver
|p open_access
|p openaire
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-588)IDM01070
|a RWTH Aachen
|b 0
|k RWTH
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-82)IDM00476
|a RWTH Aachen
|b 1
|k RWTH
914 1 _ |y 2020
915 _ _ |0 LIC:(DE-HGF)CCBY4
|2 HGFVOC
|a Creative Commons Attribution CC BY 4.0
915 _ _ |0 StatID:(DE-HGF)0510
|2 StatID
|a OpenAccess
920 1 _ |0 I:(DE-82)416110_20140620
|k 416110
|l Lehrstuhl für Chemische Verfahrenstechnik und Institut für Verfahrenstechnik
|x 0
980 1 _ |a FullTexts
980 _ _ |a I:(DE-82)416110_20140620
980 _ _ |a UNRESTRICTED
980 _ _ |a VDB
980 _ _ |a book
980 _ _ |a phd


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21