h1

h2

h3

h4

h5
h6
% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@ARTICLE{Collaboration:817803,
      author       = {Wagner, T. and Nass, A. and Pretz, Jörg and Abusaif, F.
                      and Aggarwal, A. and Andres, A. and Bekman, I. and Canale,
                      N. and Ciepal, I. and Ciullo, G. and Dahmen, F. and Dymov,
                      S. and Ehrlich, C. and Gebel, R. and Grigoryev, K. and
                      Grzonka, D. and Hejny, V. and Hetzel, J. and Kacharava, A.
                      and Kamerdzhiev, V. and Karanth, S. and Keshelashvili, I.
                      and Kononov, A. and Kulikov, A. and Laihem, K. and Lehrach,
                      Andreas and Lenisa, P. and Lomidze, N. and Magiera, A. and
                      Mchedlishvili, D. and Müller, F. and Nikolaev, N. N. and
                      Pesce, A. and Poncza, V. and Rathmann, F. and Retzlaff, M.
                      and Saleev, A. and Schmühl, M. and Shergelashvili, D. and
                      Shmakova, V. and Slim, Jamal and Stahl, Achim and
                      Stephenson, E. and Ströher, H. and Tabidze, M. and
                      Tagliente, G. and Talman, R. and Uzikov, Y. and Valdau, Y.
                      and Wrońska, A.},
      collaboration = {{JEDI Collaboration}},
      title        = {{B}eam-based alignment at the {C}ooler {S}ynchrotron {COSY}
                      as a prerequisite for an electric dipole moment measurement},
      journal      = {Journal of Instrumentation},
      volume       = {16},
      number       = {2},
      issn         = {1748-0221},
      address      = {London},
      publisher    = {Inst. of Physics},
      reportid     = {RWTH-2021-04104},
      pages        = {T02001},
      year         = {2021},
      keywords     = {Juelich COSY PS (INSPIRE) / beam position: monitoring
                      (INSPIRE) / calibration (INSPIRE) / charged particle:
                      trajectory (INSPIRE) / deuteron: electric moment (INSPIRE) /
                      magnetic field: effect (INSPIRE) / measurement methods
                      (INSPIRE) / p: electric moment (INSPIRE) / p: polarized beam
                      (INSPIRE) / quadrupole lens: alignment (INSPIRE) / spatial
                      resolution (INSPIRE) / Beam dynamics (autogen) / Beam-line
                      instrumentation (beam position and profile monitors;
                      beam-intensity monitors; bunch length monitors) (autogen) /
                      Hardware and accelerator control systems (autogen)},
      cin          = {134820 / 130000 / 133510 / 080023 / 134005 / 613110 /
                      139520},
      ddc          = {610},
      cid          = {$I:(DE-82)134820_20140620$ / $I:(DE-82)130000_20140620$ /
                      $I:(DE-82)133510_20140620$ / $I:(DE-82)080023_20140620$ /
                      $I:(DE-82)134005_20180710$ / $I:(DE-82)613110_20140620$ /
                      $I:(DE-82)139520_20140620$},
      typ          = {PUB:(DE-HGF)16},
      UT           = {WOS:000625189300001},
      doi          = {10.1088/1748-0221/16/02/t02001},
      url          = {https://publications.rwth-aachen.de/record/817803},
}