h1

h2

h3

h4

h5
h6
000836436 001__ 836436
000836436 005__ 20230914141717.0
000836436 0247_ $$2HBZ$$aHT021182355
000836436 0247_ $$2Laufende Nummer$$a40942
000836436 0247_ $$2datacite_doi$$a10.18154/RWTH-2021-11307
000836436 020__ $$a978-3-95806-593-2
000836436 037__ $$aRWTH-2021-11307
000836436 041__ $$aEnglish
000836436 082__ $$a530
000836436 1001_ $$0P:(DE-588)1248167600$$aShokoohimehr, Pegah$$b0$$urwth
000836436 245__ $$aNanostraw- Nanocavity MEAs as a new tool for long-term and high sensitive recording of neuronal signals$$cvorgelegt von Pegah Shokoohimehr, M.Sc.$$honline, print
000836436 260__ $$aJülich$$bForschungszentrum Jülich GmbH, Zentralbibliothek, Verlag$$c2021
000836436 260__ $$c2022
000836436 300__ $$a1 Online-Ressource : Illustrationen
000836436 3367_ $$02$$2EndNote$$aThesis
000836436 3367_ $$0PUB:(DE-HGF)11$$2PUB:(DE-HGF)$$aDissertation / PhD Thesis$$bphd$$mphd
000836436 3367_ $$0PUB:(DE-HGF)3$$2PUB:(DE-HGF)$$aBook$$mbook
000836436 3367_ $$2BibTeX$$aPHDTHESIS
000836436 3367_ $$2DRIVER$$adoctoralThesis
000836436 3367_ $$2DataCite$$aOutput Types/Dissertation
000836436 3367_ $$2ORCID$$aDISSERTATION
000836436 4900_ $$aSchriften des Forschungszentrums Jülich. Reihe Information$$v76
000836436 502__ $$aDissertation, RWTH Aachen University, 2021$$bDissertation$$cRWTH Aachen University$$d2021$$gFak01$$o2021-04-29
000836436 500__ $$aDruckausgabe: 2021. - Onlineausgabe: 2021. - Auch veröffentlicht auf dem Publikationsserver der RWTH Aachen University 2022
000836436 5203_ $$aDie elektrische Messung neuronaler Signale hat grundlegende Entdeckungen in den Neurowissenschaften ermöglicht. Die Patch-Clamp-Methode, als wichtiger Standard elektrophysiologischer Messungen, hat als erste Methode einen Zugang zum Innersten der Zelle mittels einer Elektrode realisiert. Mit dieser Methode ist die Aufzeichnung der Signale aus dem gesamten Spektrum der Membranpotentiale, vom Aktionspotential bis hin zu unterschwelligen Signalen, wie post-synaptischen Potentialen, möglich. Aufgrund ihres invasiven Charakters ist eine langfristige Messung von Zellen schwierig. Extrazelluläre Elektroden, wie z.B. Mikroelektroden-Arrays, ermöglichen dagegen auch langfristige Messungen von neuronalen Netzwerken. Mit diesen Elektroden kann jedoch nur ein Bruchteil der auftretenden Aktionspotentiale gemessen werden. Das ist auf das Fehlen einer starken Zell-Elektroden-Verbindung und das damit einhergehende hohe Rauschen der Elektroden zurückzuführen. Daher hat sich die Forschung der letzten Jahrzehnte hauptsächlich auf die Lösung dieses Problems konzentriert. Die Entwicklung von vertikalen 3D-Nanoelektroden ermöglichte einen ersten, vielversprechenden Zugang zum Zellinneren. Das geschah jedoch in den meisten Fällen nur mit Hilfe äußerer Kräfte wie Opto/Elektro-Poration. Deswegen sind diese transienten Methoden für langfristige Messungen nicht geeignet.In dieser Arbeit habe ich Nanostruktur-Mikroelektroden entwickelt, indem ich die Vorteile von Nanoröhren sowie von Nanokavitäten kombinierte. Während die Verwendung von Nano-Röhren das Eindringen in die Zellmembran ermöglicht, sorgen Nanokavitäten für einen hohen Abdichtwiderstand. Spontane elektrophysiologische Messungen mit unseren Nanoelektroden zeigen sowohl extrazelluläre als auch intrazelluläre (in 20 % der Fälle) Aktionspotentiale kortikaler Rattenneuronen über einen langen Zeitraum. Der Ansatz erlaubt somit kontinuierliche Messungen mit einem hohen Signal-Rausch-Verhältniss, hoher Empfindlichkeit sowie die Möglichkeit post-synaptische Potentiale aufzuzeichnen. Um die räumliche Auflösung der Messungen von neuronalen Netzwerken weiter zu verbessern, können unsere Nanoelektroden in CMOS-Geräte integriert werden. Dies ist für neurophysiologischen Studien von großem Interesse.$$lger
000836436 520__ $$aElectrical measurement of neuronal signals has enabled fundamental discoveries in neuroscience. Patch clamp method as a key standard of electrophysiological device has been shown an access to the interior single cell using an electrode. Via this method recording of the signals from the entire spectrum of the membrane potentials, from action potential down to sub-threshold signals such as post synaptic potentials, is feasible. Due to the invasive nature of this method, long term recording of the cell is challenging. Extracellular electrodes, such as microelectrode arrays, in contrast enable long term recordings of neuronal networks. However, these electrodes can only measure a fraction of the action potentials, which is due to the lack of proper cell-electrode coupling and high noise of the electrodes. Research in the last decade has been focused on overcoming these limitations. Development of the vertical 3D nanoelectrodes has allowed to access the cell’s interior, however in most cases after the application of external forces such as opto/electro-poration, and therefore these transient methods are not suitable for long term recordings.In this thesis, I developed nanostructure microelectrodes by associating two approaches of nanostraws and nanocavities. Using nanostraws facilitate penetration to the cell membrane, and the introduction of nanocavities provide high seal-resistance. The spontaneous electrophysiological recording using our nanoelectrodes demonstrate both extracellular and intracellular (20% of cases) action potentials of cortical rat neurons over long period of time. This approach enables the continuous high signal to noise ratio recordings with high sensitivity and the ability to record post synaptic potentials. To further improve the spatial resolution of neuronal network recordings, our nanoelectrodes can be integrated to CMOS-devices, which is of great interest for the neurophysiological studies.$$leng
000836436 588__ $$aDataset connected to Lobid/HBZ
000836436 591__ $$aGermany
000836436 653_7 $$aMEAs
000836436 653_7 $$acell-electrode interactions
000836436 653_7 $$along-term recordings
000836436 653_7 $$ananostraw
000836436 7001_ $$0P:(DE-82)IDM04455$$aOffenhäusser, Andreas$$b1$$eThesis advisor$$urwth
000836436 7001_ $$0P:(DE-82)187696$$aFitter, Joerg$$b2$$eThesis advisor$$urwth
000836436 8564_ $$uhttps://publications.rwth-aachen.de/record/836436/files/836436.pdf$$yOpenAccess
000836436 8564_ $$uhttps://publications.rwth-aachen.de/record/836436/files/836436_source.doc$$yRestricted
000836436 8564_ $$uhttps://publications.rwth-aachen.de/record/836436/files/836436_source.docx$$yRestricted
000836436 8564_ $$uhttps://publications.rwth-aachen.de/record/836436/files/836436_source.odt$$yRestricted
000836436 909CO $$ooai:publications.rwth-aachen.de:836436$$popenaire$$popen_access$$pVDB$$pdriver$$pdnbdelivery
000836436 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000836436 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000836436 9141_ $$y2021
000836436 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-588)1248167600$$aRWTH Aachen$$b0$$kRWTH
000836436 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)IDM04455$$aRWTH Aachen$$b1$$kRWTH
000836436 9101_ $$0I:(DE-588b)36225-6$$6P:(DE-82)187696$$aRWTH Aachen$$b2$$kRWTH
000836436 9201_ $$0I:(DE-82)134210_20140620$$k134210$$lLehrstuhl für Experimentalphysik IV B (FZ Jülich)$$x0
000836436 9201_ $$0I:(DE-82)130000_20140620$$k130000$$lFachgruppe Physik$$x1
000836436 961__ $$c2022-02-03T15:40:43.019524$$x2021-12-03T18:09:33.566068$$z2022-02-03T15:40:43.019524
000836436 9801_ $$aFullTexts
000836436 980__ $$aI:(DE-82)130000_20140620
000836436 980__ $$aI:(DE-82)134210_20140620
000836436 980__ $$aUNRESTRICTED
000836436 980__ $$aVDB
000836436 980__ $$abook
000836436 980__ $$aphd