h1

h2

h3

h4

h5
h6


001     844852
005     20250709122923.0
020 _ _ |a 978-3-8440-8543-3
024 7 _ |2 HBZ
|a HT021367361
024 7 _ |2 Laufende Nummer
|a 41161
024 7 _ |2 DOI
|a 10.2370/9783844085433
037 _ _ |a RWTH-2022-04263
041 _ _ |a English
082 _ _ |a 620
100 1 _ |0 P:(DE-82)IDM05270
|a Schöps, Malte
|b 0
|u rwth
245 _ _ |a Design, verification and validation of a novel large-volume production of ghost cells
|c Malte Schöps
|h print, online
246 _ 3 |a Konstruktion, Verifizierung und Validierung einer neuartigen Großmengenproduktion von Ghost Cells
|y German
260 _ _ |a Düren
|b Shaker Verlag
|c 2022
300 _ _ |a XI, 122 Seiten : Illustrationen, Diagramme
336 7 _ |0 2
|2 EndNote
|a Thesis
336 7 _ |0 PUB:(DE-HGF)11
|2 PUB:(DE-HGF)
|a Dissertation / PhD Thesis
|b phd
|m phd
336 7 _ |0 PUB:(DE-HGF)3
|2 PUB:(DE-HGF)
|a Book
|m book
336 7 _ |2 BibTeX
|a PHDTHESIS
336 7 _ |2 DRIVER
|a doctoralThesis
336 7 _ |2 DataCite
|a Output Types/Dissertation
336 7 _ |2 ORCID
|a DISSERTATION
490 0 _ |a Aachener Beiträge zur Medizintechnik
|v 68
500 _ _ |a Abweichender Titel auf dem Buchrücken
502 _ _ |a Dissertation, RWTH Aachen University, 2021
|b Dissertation
|c RWTH Aachen University
|d 2021
|g Fak04
|o 2021-11-16
520 3 _ |a (1) Mechanische Herz-Kreislauf-Unterstützung basiert größtenteils auf bewegten Aktoren im Organismus Blut, wie beispielsweise die Rotoren von Zentrifugalblutpumpen. Sobald diese Systeme bei der Therapie von Patienten zum Einsatz kommen, wird das Blut außerordentlichen Belastungen ausgesetzt. Die Hämolyse ist, neben der Thrombozytenaktivierung, nach wie vor eine der größten Herausforderungen bei der Entwicklung von mechanischen Herz-Kreislauf-Unterstützungssystemen. Sobald die Schubspannungen einen Schwellwert überschreiten, reißt die Membran der roten Blutkörperchen und führt zu deren Zerstörung — der Hämolyse. (2) Um dieses Phänomen genauer zu untersuchen, entwickelten Jansen et al. die sogenannte Fluorescent Haemolysis Detection Method (FHDM). Mit dieser Methode wird zusätzlich zu der bisher bewährten zeitlichen und quantitativen Hämolyse-Evaluierung auch eine räumliche Auflösung auf Basis von Ghost Cells realisiert. Ghost cells bezeichnen rote Blutkörperchen mit reduzierter intrazellulärer Hämoglobinkonzentration. Limitiert ist die FHDM jedoch durch das geringe Volumen an Ghost Cells, das bisher produziert werden konnte. Größere Volumina würden es erlauben, diese Methode auch an mechanischen Herz-Kreislauf-Unterstützungssystemen realer Größe und gemäß internationaler Normen durchzuführen. (3) Durch die Implementierung einer Halbautomatisierung in das etablierte manuelle Verfahren mittels eines neuartigen Großvolumen-Batch-Produktionssystems (LVBPS) konnte die Produktivität um das 22-fache und die Effizienz um das 34-fache erhöht werden. Zeitaufwändige manuelle Arbeiten wie z. B. das Pipettieren, werden nun durch sensorgesteuerte Verfahrenstechnik automatisiert. Neben der gesteigerten Effizienz sorgt die Prozessüberwachung für konstante Prozessparameter und für eine Teilautomatisierung der Produktion. Darüber hinaus konnten die Eigenschaften des Blutersatzfluids wie Rheologie und Verformbarkeit im Vergleich zur manuellen Produktion beibehalten oder sogar verbessert werden. Mit Hilfe des LVBPS wurde das Ziel, große Mengen an Ghost Cells herstellen zu können, erfolgreich umgesetzt.
|l ger
520 _ _ |a (1) Mechanical circulatory support is mainly based on moving actuators in the organism blood, such as the blades of centrifugal blood pumps. Using these devices in the treatment of patients exposes blood to unusual stress, causing hemolysis. Hemolysis is still one of the major challenges in the development of mechanical circulatory support devices, apart from thrombocyte activation. Close to the surface between rotor and blood, high shear stress acts on red blood cells. As soon as shear stress exceeds a threshold value, it leads to hemolysis, destroying red blood cells by rupturing their membranes. (2) The fluorescent hemolysis detection method (FHDM) developed by Jansen et al. investigates hemolysis in more detail. With this method, a spatial resolution of hemolysis hotspots is realized based on ghost cells. Ghost cells are red blood cells with reduced intracellular hemoglobin. The FHDM is limited by the small amounts of ghost cells produced. Larger volumes would allow to perform this method even according to international standards and on real size models of mechanical circulatory support systems. The aim of this study was to develop a process engineering system using semi-automatic mechatronic technology to increase ghost cell production volume. (3) Until now, production volume was limited to 10.3 mL of ghost cells with a hematocrit of 30 % due to predominantly manual process steps. By implementation of a novel semi-automated large-volume batch production system (LVBPS) in the existing method, productivity was increased 22-fold while multiplying process efficiency by 34 times. Time-consuming manual work such as pipetting was supported by sensor-based process engineering. In addition to increased efficiency, process monitoring was implemented in the system to ensure consistent process parameters and semi-automation of the production process. Moreover, the properties of ghost cells as blood substitute such as rheology and deformability were maintained or even enhanced compared to manual production. With the help of the LVBPS, the objective of producing large volumes of ghost cells was successfully achieved.
|l eng
536 _ _ |0 G:(GEPRIS)321130633
|a Fluorescent Hemolysis Detection (FHD): Validierung der In-vitro Testmethode (321130633)
|c 321130633
|x 0
588 _ _ |a Dataset connected to DataCite
591 _ _ |a Germany
653 _ 7 |a Automatisierung
653 _ 7 |a FHDM
653 _ 7 |a Hämolyse
653 _ 7 |a automation
653 _ 7 |a fluorescent hemolysis detection method
653 _ 7 |a ghost cells
653 _ 7 |a hemolysis
653 _ 7 |a räumlich aufgelöste Hämolyse-Detektion
653 _ 7 |a spatially resolved hemolysis detection
700 1 _ |0 P:(DE-82)000567
|a Steinseifer, Ulrich
|b 1
|e Thesis advisor
|u rwth
700 1 _ |0 P:(DE-82)IDM01256
|a Jupke, Andreas
|b 2
|e Thesis advisor
|u rwth
909 C O |o oai:publications.rwth-aachen.de:844852
|p VDB
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-82)IDM05270
|a RWTH Aachen
|b 0
|k RWTH
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-82)000567
|a RWTH Aachen
|b 1
|k RWTH
910 1 _ |0 I:(DE-588b)36225-6
|6 P:(DE-82)IDM01256
|a RWTH Aachen
|b 2
|k RWTH
914 1 _ |y 2022
920 1 _ |0 I:(DE-82)811001-1_20140620
|k 811001-1
|l Institut und Lehrstuhl für Angewandte Medizintechnik
|x 0
920 1 _ |0 I:(DE-82)416310_20151215
|k 416310
|l Lehrstuhl für Fluidverfahrenstechnik
|x 1
980 _ _ |a I:(DE-82)416310_20151215
980 _ _ |a I:(DE-82)811001-1_20140620
980 _ _ |a UNRESTRICTED
980 _ _ |a VDB
980 _ _ |a book
980 _ _ |a phd


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21