| 245 | _ | _ | |a Effiziente statische Spannungshaltung in Verteilungsnetzen mit innovativen Blindleistungsverfahren |c vorgelegt von Marian Meyer-Vomberg M.Sc. M.Sc. (RWTH Aachen) |h online |
| 260 | _ | _ | |a Aachen |b RWTH Aachen University |c 2023 |
| 300 | _ | _ | |a 1 Online-Ressource : Illustrationen, Diagramme |
| 336 | 7 | _ | |0 2 |2 EndNote |a Thesis |
| 336 | 7 | _ | |0 PUB:(DE-HGF)11 |2 PUB:(DE-HGF) |a Dissertation / PhD Thesis |b phd |m phd |
| 336 | 7 | _ | |2 BibTeX |a PHDTHESIS |
| 336 | 7 | _ | |2 DRIVER |a doctoralThesis |
| 336 | 7 | _ | |2 DataCite |a Output Types/Dissertation |
| 336 | 7 | _ | |2 ORCID |a DISSERTATION |
| 500 | _ | _ | |a Veröffentlicht auf dem Publikationsserver der RWTH Aachen University |
| 502 | _ | _ | |a Dissertation, Rheinisch-Westfälische Technische Hochschule Aachen, 2023 |b Dissertation |c Rheinisch-Westfälische Technische Hochschule Aachen |d 2023 |g Fak06 |o 2023-03-24 |
| 520 | 3 | _ | |a Die vorliegende Arbeit behandelt die statische Spannungshaltung mit Blindleistungsregelungen in Verteilnetzen. Es wird ein neuartiges Blindleistungsregelungsverfahren vorgestellt, welches bei gleicher Effektivität hinsichtlich des Integrationspotentials die durch Blindleistung verursachten Anlagen- und Netzverluste um 70-90 % gegenüber dem Stand der Technik reduzieren kann. Dies korreliert mit signifikanten wirtschaftlichen Einsparungen bei Netz- und Anlagenbetreibern. Das entwickelte Blindleistungsverfahren wird als Q(U(P))-Regelung bezeichnet. Abhängig von der lokalen Wirkleistungseinspeisung wird ein Spannungsgrenzwert bestimmt, auf den mittels Integral-Regler die Spannung am Netzverknüpfungspunkt geregelt wird. Das neue Verfahren wird mit der klassischen Q(U)-Kennlinie nach VDE AR-N 4105 und einem aus der Literatur entnommenen Verfahren cosφ(P, U) verglichen. Das Verfahren cosφ(P, U) basiert auf der klassischen cosφ(P)-Steuerung, bei einer niedrigen lokalen Spannung wird die Blindleistung jedoch abgeschwächt. Die drei Verfahren sind dezentrale Blindleistungsregelungen, die auf Wechselrichtern für Photovoltaikanlagen implementiert werden. Es wird für die drei Verfahren das Integrationspotential abhängig von der Parametrierung bestimmt. Dabei zeigt sich bei allen untersuchten Wechselrichter-Arbeitsbereichen eine identische Abhängigkeit des Integrationspotentials von der Parametrierung des Verfahrens. Bei hohen Spannungen am Netzverknüpfungspunkt kann das Integrationspotential durch Blindleistungsverfahren übereinstimmend um 40 % er-höht werden. Die Verfahren sind ähnlich effektiv, da weitere Restriktionen wie die Belastbarkeit von Leitungen und Transformatoren begrenzend wirken. Unterschiede in der Spannungshaltung sind daher nicht Praxisrelevant. Bei der Effizienz zeigen sich große Unterschiede zwischen den Verfahren. Bei einem identischen Integrationspotential kann mittels Verwendung von Q(U(P)) statt Q(U) als Regelungsverfahren die von Blindleistung verursachten Netzverluste um 70-90 % gesenkt werden. Die Effizienz der Spannungsregelung mittels Einsatz von dezentraler Blindleistung kann in der Niederspannung auch mit Kommunikationstechnik nicht mehr signifikant gesteigert werden. |l ger |
| 520 | _ | _ | |a This thesis deals with static voltage stability with reactive power control in distribution grids. A new, decentralised reactive power control method is presented, which can reduce the inverter and grid losses caused by reactive power by 70-90 % compared to the state of the art control. The control method has the same effectiveness with regard to the hosting capacity. The reduced losses correlate with significant economic savings for grid and plant operators. The developed reactive power method is called Q(U(P)). Depending on the local active power feed-in, a voltage limit is determined to which the voltage at the grid interconnection point is regulated by the inverter using an integral controller block. The new method is compared with the state of the art Q(U) characteristic according to VDE AR-N 4105 and a method called cosφ(P, U) taken from the scientific literature. The cosφ(P, U) method is based on the classic cosφ(P) control, but at a low local voltage the reactive power is attenuated. The three methods are decentralised reactive power controls that are implemented on inverters for photovoltaic generators. The integration potential is determined for the three methods depending on the parameterisation. An identical dependency of the integration potential on the voltage parameterisation is found for all inverter operating ranges investigated. At high voltages at the grid interconnection point, the integration potential can be increased by 40 % by reactive power methods. The methods are similarly effective, since further restrictions such as the loading capacity of lines and transformers have a limiting effect. Differences in the voltage management are therefore not relevant in practice. In terms of efficiency, there are major differences between the methods. With an identical hosting capacity, the grid losses caused by reactive power can be reduced by 70-90 % by using Q(U(P)) instead of Q(U) as a control method. The efficiency of voltage regulation using decentralised reactive power cannot be significantly improved in low voltage grids any further. Even with the usage of communication technology improvements are marginal. |l eng |
| 588 | _ | _ | |a Dataset connected to Lobid/HBZ |
| 591 | _ | _ | |a Germany |
| 653 | _ | 7 | |a Blindleistung |
| 653 | _ | 7 | |a Spannungshaltung |
| 700 | 1 | _ | |0 P:(DE-82)IDM05905 |a Ulbig, Andreas |b 1 |e Thesis advisor |u rwth |
| 700 | 1 | _ | |a Engel, Bernd |b 2 |e Thesis advisor |
| 856 | 4 | _ | |u https://publications.rwth-aachen.de/record/962234/files/962234.pdf |y OpenAccess |
| 856 | 4 | _ | |u https://publications.rwth-aachen.de/record/962234/files/962234_source.docx |y Restricted |
| 909 | C | O | |o oai:publications.rwth-aachen.de:962234 |p dnbdelivery |p driver |p VDB |p open_access |p openaire |
| 910 | 1 | _ | |0 I:(DE-588b)36225-6 |6 P:(DE-588)1299399762 |a RWTH Aachen |b 0 |k RWTH |
| 910 | 1 | _ | |0 I:(DE-588b)36225-6 |6 P:(DE-82)IDM05905 |a RWTH Aachen |b 1 |k RWTH |
| 914 | 1 | _ | |y 2023 |
| 915 | _ | _ | |0 StatID:(DE-HGF)0510 |2 StatID |a OpenAccess |
| 920 | 1 | _ | |0 I:(DE-82)614010_20200506 |k 614010 |l Lehrstuhl für Aktive Energieverteilnetze |x 0 |
| 980 | 1 | _ | |a FullTexts |
| 980 | _ | _ | |a I:(DE-82)614010_20200506 |
| 980 | _ | _ | |a UNRESTRICTED |
| 980 | _ | _ | |a VDB |
| 980 | _ | _ | |a phd |
| Library | Collection | CLSMajor | CLSMinor | Language | Author |
|---|