<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
<record>
  <controlfield tag="001">972892</controlfield>
  <controlfield tag="005">20251006144958.0</controlfield>
  <datafield tag="024" ind1="7" ind2=" ">
    <subfield code="2">HBZ</subfield>
    <subfield code="a">HT030402829</subfield>
  </datafield>
  <datafield tag="024" ind1="7" ind2=" ">
    <subfield code="2">Laufende Nummer</subfield>
    <subfield code="a">42679</subfield>
  </datafield>
  <datafield tag="024" ind1="7" ind2=" ">
    <subfield code="2">datacite_doi</subfield>
    <subfield code="a">10.18154/RWTH-2023-10452</subfield>
  </datafield>
  <datafield tag="037" ind1=" " ind2=" ">
    <subfield code="a">RWTH-2023-10452</subfield>
  </datafield>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">English</subfield>
  </datafield>
  <datafield tag="082" ind1=" " ind2=" ">
    <subfield code="a">624</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="0">P:(DE-588)1309982708</subfield>
    <subfield code="a">Gokarakonda, Sriraj</subfield>
    <subfield code="b">0</subfield>
    <subfield code="u">rwth</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2=" ">
    <subfield code="a">Energy performance, potential and optimisation of mixed-mode buildings in India</subfield>
    <subfield code="c">vorgelegt von Sriraj Gokarakonda</subfield>
    <subfield code="h">online</subfield>
  </datafield>
  <datafield tag="246" ind1=" " ind2="3">
    <subfield code="a">Energieleistung, Potenzial und Optimierung von Mixed-Mode-Gebäuden in Indien</subfield>
    <subfield code="y">German</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Aachen</subfield>
    <subfield code="b">RWTH Aachen University</subfield>
    <subfield code="c">2023</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">1 Online-Ressource : Illustrationen, Diagramme</subfield>
  </datafield>
  <datafield tag="336" ind1="7" ind2=" ">
    <subfield code="0">2</subfield>
    <subfield code="2">EndNote</subfield>
    <subfield code="a">Thesis</subfield>
  </datafield>
  <datafield tag="336" ind1="7" ind2=" ">
    <subfield code="0">PUB:(DE-HGF)11</subfield>
    <subfield code="2">PUB:(DE-HGF)</subfield>
    <subfield code="a">Dissertation / PhD Thesis</subfield>
    <subfield code="b">phd</subfield>
    <subfield code="m">phd</subfield>
  </datafield>
  <datafield tag="336" ind1="7" ind2=" ">
    <subfield code="2">BibTeX</subfield>
    <subfield code="a">PHDTHESIS</subfield>
  </datafield>
  <datafield tag="336" ind1="7" ind2=" ">
    <subfield code="2">DRIVER</subfield>
    <subfield code="a">doctoralThesis</subfield>
  </datafield>
  <datafield tag="336" ind1="7" ind2=" ">
    <subfield code="2">DataCite</subfield>
    <subfield code="a">Output Types/Dissertation</subfield>
  </datafield>
  <datafield tag="336" ind1="7" ind2=" ">
    <subfield code="2">ORCID</subfield>
    <subfield code="a">DISSERTATION</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Veröffentlicht auf dem Publikationsserver der RWTH Aachen University</subfield>
  </datafield>
  <datafield tag="502" ind1=" " ind2=" ">
    <subfield code="a">Dissertation, Rheinisch-Westfälische Technische Hochschule Aachen, 2023</subfield>
    <subfield code="b">Dissertation</subfield>
    <subfield code="c">Rheinisch-Westfälische Technische Hochschule Aachen</subfield>
    <subfield code="d">2023</subfield>
    <subfield code="g">Fak03</subfield>
    <subfield code="o">2023-10-23</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Die meisten Gebäude in Indien werden als Mixed-Mode Buildings (MMBs) betrieben, die je nach Wetterlage entweder voll klimatisiert oder natürlich belüftet sind. Der Energieverbrauch für die Raumkühlung ist eine wichtige Endverbraucherleistung in Gebäuden. Es wird erwartet, dass die Klimatisierung aufgrund der hohen Wachstumsschätzungen im Gebäudebau, des Verkaufs von Raumklimageräten und des realen Einkommenswachstums erheblich zunehmen wird. In dieser Arbeit werden daher die einflussreichsten Konstruktions- und Steuerungsparameter untersucht, die das Potenzial von MMBs in Indien in Bezug auf ihre thermische und energetische Effizienz beeinflussen. Die wichtigsten Merkmale von MMBs, die im Rahmen des Forschungsprojekts analysiert werden, sind folgende: Das Schließen der Fenster in der Nacht macht die Nachtlüftung unpraktisch; die natürliche Belüftung durch Deckenventilatoren und Fenster wird genutzt, um optimale thermische Bedingungen im natürlich belüfteten Modus aufrechtzuerhalten, und RACs werden im klimatisierten Modus eingesetzt. In dieser Arbeit werden drei Forschungsfragen gestellt, die es zu beantworten gilt. Erstens: Welche Forschungslücken gibt es bei der Bewertung der thermischen und energetischen Leistung von gemischt genutzten Gebäuden in Indien? Zweitens: Welches Potenzial haben sie in Bezug auf die wichtigsten Betriebsbedingungen, und welche Parameter beeinflussen dieses Potenzial? Und schließlich: Wie können diese einflussreichen Parameter optimiert werden? Um diese Fragen zu beantworten, wurden drei Forschungsmethoden angewandt: 1) Literaturrecherche; 2) groß angelegte Simulation der Gebäudeenergieeffizienz in Verbindung mit einer Unsicherheits- und Sensitivitätsanalyse; und 3) Feldstudien zum Nutzerverhalten in Bezug auf RACs und zu den Auswirkungen von Deckenventilatoren und RACs auf die Innenraumbedingungen und den Energieverbrauch. Insgesamt wurde in der Studie die Kühlsollwerttemperatur als der einflussreichste Steuerungsparameter ermittelt. In der Studie wurde die Kühlsollwerttemperatur als der einflussreichste Regelungsparameter ermittelt. Im Allgemeinen wurden die Eingangsparameter, die sich auf das Gebäudedesign, die Form und die Geometrie beziehen, als wichtiger angesehen als die Parameter, die sich auf die Konstruktion beziehen. Die Studie hebt ferner hervor, dass eine Solltemperatur von 28 oder 30°C ausreicht, um den Innenraumkomfort gemäß dem indischen Modell für adaptiven Komfort (IMAC) für Wohngebäude aufrechtzuerhalten. Wenn ein bestimmter Luftstrom erforderlich ist, wäre es am besten, den Deckenventilator mit einer niedrigen Drehzahl zu betreiben, die im Allgemeinen auf 1 eingestellt ist.</subfield>
    <subfield code="l">ger</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Most air-conditioned buildings in India operate as Mixed-Mode Buildings (MMBs), either fully air-conditioned or with natural ventilation depending on the weather. Energy consumption for space cooling is a vital end-use service in buildings. Air-conditioning is expected to increase significantly due to high growth estimates in building construction, sales of Room Air-Conditioners (RACs), and real income growth. Therefore, this thesis examines the most influential design and control parameters that influence the potential of MMBs in India in relation to their thermal and energy performance. The primary features of MMBs analysed in the research project are as follows: shutting windows at night makes night ventilation redundant; natural ventilation through ceiling fans and windows is utilised to maintain optimal thermal conditions in naturally-ventilated mode and RACs are employed in air-conditioned mode. This thesis poses three research questions and aims to answer them. Firstly, what are the research gaps in assessing thermal and energy performance in mixed-mode buildings in India? Secondly, what is their potential concerning key operating conditions, and which parameters affect this potential? Lastly, how can these influential parameters be optimised? To answer these questions, three research methods were employed: 1) literature review; 2) large-scale simulation of building energy performance combined with uncertainty and sensitivity analysis; and 3) field studies of user behaviour with regards to RACs and the impact of ceiling fans and RACs on indoor conditions and energy consumption. The study identifies the cooling set point temperature as the most influential control parameter. In general, input parameters related to building design, shape and geometry were considered more important than those related to construction parameters. Furthermore, the study highlights that a set point temperature of 28 or 30°C is sufficient to maintain indoor comfort according to the Indian Model for Adaptive Comfort (IMAC) for residential buildings. If a specific airflow is required, it would use the least energy to run the ceiling fan at a low speed, usually set at 1.</subfield>
    <subfield code="l">eng</subfield>
  </datafield>
  <datafield tag="588" ind1=" " ind2=" ">
    <subfield code="a">Dataset connected to Lobid/HBZ</subfield>
  </datafield>
  <datafield tag="591" ind1=" " ind2=" ">
    <subfield code="a">Germany</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2="7">
    <subfield code="a">building energy performance</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2="7">
    <subfield code="a">ceiling fan</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2="7">
    <subfield code="a">mixed-mode buildings</subfield>
  </datafield>
  <datafield tag="653" ind1=" " ind2="7">
    <subfield code="a">room air-conditioner</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="0">P:(DE-82)IDM00787</subfield>
    <subfield code="a">van Treeck, Christoph Alban</subfield>
    <subfield code="b">1</subfield>
    <subfield code="e">Thesis advisor</subfield>
    <subfield code="u">rwth</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Rawal, Rajan</subfield>
    <subfield code="b">2</subfield>
    <subfield code="e">Thesis advisor</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">http://publications.rwth-aachen.de/record/972892/files/972892.pdf</subfield>
    <subfield code="y">OpenAccess</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2=" ">
    <subfield code="u">http://publications.rwth-aachen.de/record/972892/files/972892_source.zip</subfield>
    <subfield code="y">Restricted</subfield>
  </datafield>
  <datafield tag="909" ind1="C" ind2="O">
    <subfield code="o">oai:publications.rwth-aachen.de:972892</subfield>
    <subfield code="p">dnbdelivery</subfield>
    <subfield code="p">driver</subfield>
    <subfield code="p">VDB</subfield>
    <subfield code="p">open_access</subfield>
    <subfield code="p">openaire</subfield>
  </datafield>
  <datafield tag="910" ind1="1" ind2=" ">
    <subfield code="0">I:(DE-588b)36225-6</subfield>
    <subfield code="6">P:(DE-588)1309982708</subfield>
    <subfield code="a">RWTH Aachen</subfield>
    <subfield code="b">0</subfield>
    <subfield code="k">RWTH</subfield>
  </datafield>
  <datafield tag="910" ind1="1" ind2=" ">
    <subfield code="0">I:(DE-588b)36225-6</subfield>
    <subfield code="6">P:(DE-82)IDM00787</subfield>
    <subfield code="a">RWTH Aachen</subfield>
    <subfield code="b">1</subfield>
    <subfield code="k">RWTH</subfield>
  </datafield>
  <datafield tag="914" ind1="1" ind2=" ">
    <subfield code="y">2023</subfield>
  </datafield>
  <datafield tag="915" ind1=" " ind2=" ">
    <subfield code="0">StatID:(DE-HGF)0510</subfield>
    <subfield code="2">StatID</subfield>
    <subfield code="a">OpenAccess</subfield>
  </datafield>
  <datafield tag="920" ind1="1" ind2=" ">
    <subfield code="0">I:(DE-82)312410_20140620</subfield>
    <subfield code="k">312410</subfield>
    <subfield code="l">Lehrstuhl für Energieeffizientes Bauen</subfield>
    <subfield code="x">0</subfield>
  </datafield>
  <datafield tag="980" ind1="1" ind2=" ">
    <subfield code="a">FullTexts</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">I:(DE-82)312410_20140620</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">UNRESTRICTED</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">VDB</subfield>
  </datafield>
  <datafield tag="980" ind1=" " ind2=" ">
    <subfield code="a">phd</subfield>
  </datafield>
</record>
</collection>