Methodische Ansätze zur Ermittlung gefährdungsbezogener Interaktionen bei Medizinprodukten in der Intensiv- und Notfallmedizin = Methodological approaches for investigating hazard-related interactions with medical devices in intensive care and emergency medicine



Verantwortlichkeitsangabevorgelegt von Beatrice Coldewey, M. Sc.

ImpressumAachen : RWTH Aachen University 2026

Umfang1 Online-Ressource : Illustrationen


Dissertation, Rheinisch-Westfälische Technische Hochschule Aachen, 2026, Kumulative Dissertation

Veröffentlicht auf dem Publikationsserver der RWTH Aachen University


Genehmigende Fakultät
Fak10

Hauptberichter/Gutachter
;

Tag der mündlichen Prüfung/Habilitation
2026-02-02

Online
DOI: 10.18154/RWTH-2026-02537
URL: https://publications.rwth-aachen.de/record/1029724/files/1029724.pdf

Einrichtungen

  1. Institut und Lehrstuhl für Medizinische Informatik (526500-2 ; 922710)

Inhaltliche Beschreibung (Schlagwörter)
medical device (frei) ; patient safety (frei) ; usability engineering (frei) ; use error (frei)

Thematische Einordnung (Klassifikation)
DDC: 610

Kurzfassung
Der Einsatz technischer Artefakte ist ein integraler Bestandteil der Intensiv- und Notfallmedizin und kann maßgeblich zur Erhöhung der Patient*innensicherheit beitragen. Gleichzeitig entstehen mit ihrer Einführung oder Modifikation neue Risiken, insbesondere im Kontext sozio-technischer Systeme. Daher ergeben sich hohe Anforderungen an die Gebrauchstauglichkeit (engl. Usability) und den Umgang mit Nutzungsfehlern (engl. use error) der in diesem Kontext eingesetzten Systeme. Ziel dieser Arbeit ist die Entwicklung und Erprobung von Methoden zur Ermittlung gefährdungsbezogener Interaktionen sowie zur Vermeidung von Nutzungsfehlern im Hinblick auf die Gebrauchstauglichkeit von Medizinprodukten. Folgende Forschungsfragen wurden untersucht: • F1: Wie können bekannte Nutzungsprobleme, die bei der Anwendung sicherheitskritischer Medizinprodukte auftreten, am Beispiel von Beatmungsgeräten systematisch ermittelt werden? • F2: Wie können dynamische Vitalwerte wie z. B. Beatmungsparameter visualisiert werden, um pathologische Veränderungen, die nur über die Zeitreihe erkennbar sind, besser wahrnehmbar zu machen? • F3: Welchen Einfluss hat die Gebrauchstauglichkeit technischer Artefakte wie z. B. automatischer externer Defibrillatoren (AEDs) in kritischen Versorgungssituationen auf die klinisch relevanten Endpunkte Effektivität und Effizienz? Im Rahmen eines systematischen Reviews nach dem PRISMA Reporting Standard konnten bei Beatmungsgeräten gerätespezifische sowie geräteübergreifende Ursachen für Nutzungsprobleme ermittelt werden. Dazu zählen die Gestaltung von Schnittstellenelementen, die Repräsentation von medizinischen Funktionen und deren Navigation (Beantwortung F1). Die Darstellung pathologischer Prozesse anhand dynamischer Vitalparameter in Medizinprodukten unterstützt bei der Erkennung kritischer Zustände und soll die medizinische Einordnung des Gesundheitszustands von Patient*innen erleichtern. Basierend auf dem Usability-Engineering Prozess wurden Beatmungsdaten analysiert, um die Darstellung und Gebrauchstauglichkeit zu verbessern. Daraus resultierten alternative Visualisierungen zur besseren Darstellung pathologischer Prozesse sowie High-Fidelity-Mockups zur Evaluation der Gebrauchstauglichkeit (Beantwortung F2). Die für die Interaktion mit Medizinprodukten benötigte Zeit ist in kritischen Situationen wie der Reanimation klinisch relevant. In einer prospektiven, randomisierten Simulationsstudie (RCT) mit Laien wurde die Bedienung zweier automatisierter externer Defibrillatoren (AED) untersucht. Dabei wurden Effektivität und Effizienz erfasst sowie potenzielle Nutzungsfehler und ihre Ursachen, die zu Verzögerungen führten, analysiert. Es konnte ein klinisch relevanter Zeitunterschied (Effizienz) von 32,5 Sekunden bis zur Schockabgabe (Effektivität) bedingt durch Unterschiede in der Gestaltung der Geräte nachgewiesen werden, der signifikant war (p<0,05) (Beantwortung F3). In dieser Arbeit wurden Methoden zur Entwicklung und Analyse von Mensch-Maschine-Schnittstellen angewendet und weiterentwickelt, um Schwachstellen in der Gebrauchstauglichkeit zu identifizieren und neue sowie bestehende Systeme systematisch zu evaluieren. Das sozio-technische System im klinischen Kontext ist dabei von zentraler Bedeutung: Variierende Bedienkonzepte bei medizinischen Geräten desselben Typs, jedoch unterschiedlicher Hersteller, können unerwartete Fehlerquellen darstellen. Zur Verbesserung der Gebrauchstauglichkeit sind künftig realitätsnahe Evaluationsstudien mit Fokus auf sicherheitsrelevante Merkmale sowie die Erprobung neuer Ansätze erforderlich. Limitationen ergaben sich durch die uneinheitliche Begriffsverwendung von Gebrauchstauglichkeit in der Literatur, technische Hürden bei der Umsetzung neuer Interfacekonzepte sowie durch die pandemiebedingte Schwierigkeit Studien durchzuführen.

Technical artefacts are an integral part of intensive care and emergency medicine and their use can have a relevant impact on patient safety. However, introducing or modifying these systems can create new risks, particularly in the context of socio-technical systems. Therefore, there are high demands on the usability and the handling of use errors of the systems used in this context. This work aims to develop and evaluate methods for investigating hazard-related interactions and preventing use errors with regard to the usability of medical devices. The following research questions were investigated: • Q1: How can errors that occur when using safety-critical medical devices, such as ventilators, be systematically identified? • Q2: How can dynamic vital signs such as ventilation parameters be visualised to make pathological changes that can only be detected via time series more perceptible? • Q3: What influence does the usability of technical artefacts, such as automated external defibrillators (AEDs), have on clinically relevant endpoints, such as effectiveness and efficiency, in critical care situations? As a result of a systematic review in accordance with the PRISMA Reporting Standard, device-specific and cross-device causes of usage problems were identified for ventilators. These include the design of interface elements and the representation of medical functions and their navigation (answer Q1). Visualising pathological processes based on dynamic vital parameters in medical devices supports the detection of critical conditions and facilitates the medical classification of patients' health. Ventilation data was analysed based on the usability engineering process in order to improve presentation and usability. This resulted in alternative visualisations to better represent pathological processes, as well as high-fidelity mock-ups to evaluate usability (answer Q2). The time required to interact with medical devices is clinically relevant in critical situations such as resuscitation. In a prospective, randomised simulation study (RCT) involving lay persons, the operation of two automated external defibrillators (AEDs) was investigated. The effectiveness and efficiency were recorded and potential use errors and their causes, which led to delays, were analyzed. A clinically relevant time difference (efficiency) of 32.5 seconds to shock delivery (effectiveness) due to differences in the design of the devices was demonstrated, which was significant (p<0.05) (answer Q3). This work applied and further developed methods for the development and analysis of human-machine interfaces in order to identify usability-related safety issues and systematically evaluate new and existing systems. In the clinical context, the socio-technical system is of central importance: operating concepts that vary between medical devices of the same type but from different manufacturers can be an unexpected source of error. To improve usability, future studies must focus on safety-relevant features and test new approaches. Limitations arose due to inconsistent usage of the term 'usability' in the literature, technical hurdles in implementing new interface concepts, and difficulties conducting studies due to the pandemic.

OpenAccess:
Volltext herunterladen PDF
(zusätzliche Dateien)

Dokumenttyp
Dissertation / PhD Thesis

Format
online

Sprache
Multiple

Externe Identnummern
HBZ: HT031417253

Interne Identnummern
RWTH-2026-02537
Datensatz-ID: 1029724

Beteiligte Länder
Germany

 GO


Related:

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Journal Article  ;  ;  ;
Causes of use errors in ventilation devices : Systematic review
Applied ergonomics 98, 103544 () [10.1016/j.apergo.2021.103544]  GO OpenAccess  Download fulltext Files BibTeX | EndNote: XML, Text | RIS

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Journal Article  ;  ;  ;  ;
Usability of Automated External Defibrillators : A Randomized, Comparative Simulator Study
International journal of human computer interaction 40(22), 6972-6983 () [10.1080/10447318.2023.2260973]  GO OpenAccess  Download fulltext Files BibTeX | EndNote: XML, Text | RIS

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Contribution to a book/Contribution to a conference proceedings  ;  ;  ;  ;
Usability Engineering of Dynamic Biosignal Displays Using Ventilation Data
Caring Is Sharing -- Exploiting the Value in Data for Health and Innovation : Proceedings of MIE 2023 / Hägglund, Maria [HerausgeberIn] ; Blusi, Madeleine ; Bonacina, Stefano
Medical Informatics Europe Conference 2023, MIE 2023, GöteborgGöteborg, Sweden, 22 May 2023 - 25 May 20232023-05-222023-05-25
Amsterdam : IOS Press, Studies in health technology and informatics 302, 626-630 () [10.3233/SHTI230224]  GO OpenAccess  Download fulltext Files BibTeX | EndNote: XML, Text | RIS


OpenAccess

QR Code for this record

The record appears in these collections:
Dokumenttypen > Qualifikationsschriften > Dissertationen
Publikationsserver / Open Access
Medizinische Fakultät (Fak.10)
Öffentliche Einträge
526500\-2
Publikationsdatenbank

 Datensatz erzeugt am 2026-03-02, letzte Änderung am 2026-03-24


Dieses Dokument bewerten:

Rate this document:
1
2
3
 
(Bisher nicht rezensiert)