h1

h2

h3

h4

h5
h6
http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png

Transosseous Suture versus Suture Anchor Fixation for Inferior Pole Fractures of the Patella in Osteoporotic Bone: A Biomechanical Study - Dataset

; ; ; ; ; ; ; ; ; ;

Online
DOI: 10.18154/RWTH-2022-02362
URL: https://publications.rwth-aachen.de/record/842324/files/Data_RWTH-2022-02362.xlsx

Einrichtungen

  1. Klinik und Lehrstuhl für Orthopädie, Unfall- und Wiederherstellungschirurgie (533500-3 ; 931510)
  2. Institut und Lehrstuhl für Molekulare und Zelluläre Anatomie (511001-4)
  3. Lehrstuhl und Institut für Allgemeine Mechanik (411110)


Inhaltliche Beschreibung (Schlagwörter)
patella fracture (frei) ; suture anchor (frei) ; transosseous suture (frei) ; biomechanical (frei) ; osteoporotic fracture (frei) ; bone mineral density (frei)

Kurzfassung
Background: The surgical treatment of inferior patellar pole fractures can be a challenge, especially in geriatric patients, who are particularly frequently affected by osteoporosis. The objective of this biomechanical study was to compare the performance of suture anchor and transosseous suture fixation in fractures of the inferior patellar pole in context of bone mineral density.Methods: Twelve fresh-frozen human cadaveric knees received a transverse osteotomy, simulating an AO/OTA 34C1.3 inferior pole fracture of the patella. These fractures were fixated with either suture anchors (SA; Corkscrew® FT 4.5 mm) or transosseous suture (TS; #2 FiberWire®). Cyclic loading tests were performed by pulling the quadriceps tendon against gravity from 90° flexion to almost full extension (5°) for 1,000 cycles. Motion and fracture gap displacement were tracked until failure occurred. Subsequently, loading to failure tests followed. Differences between groups were compared using unpaired t-tests, and correlations were calculated with Pearson’s correlation coefficient.Results: The suture anchor group showed significantly fewer cycles to failure than the transosseous suture group (SA: 539.0±465.6 cycles, TS: 1,000±0 cycles, P=0.04). Bone mineral density correlated positively with cycles to failure in the suture anchor group (Pearson’s r=0.60, P=0.02). No differences in fracture gap displacement could be proven after 100 cycles (SA: 4.1±2.6 mm, TS: 6.5±2.6 mm, P=0.19); 500 cycles (SA: 6.4±6.1 mm, TS: 9.6±3.8 mm, P=0.39); and 1,000 cycles (SA: 4.0±0.4 mm, TS: 11.0±4.5 mm, P=0.08). Furthermore, the mean destructive load to failure in the suture anchor group was also significantly lower than in the transosseous suture group (SA: 422.4±212.2 N, TS: 825.7±189.3 N, P=0.04).

OpenAccess:
Download fulltext XLSX
(additional files)

Dokumenttyp
Dataset

Sprache
English

Interne Identnummern
RWTH-2022-02362
Datensatz-ID: 842324

Beteiligte Länder
Germany

 GO


Related:

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Journal Article  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;
Transosseous suture versus suture anchor fixation for inferior pole fractures of the patella in osteoporotic bone : a biomechanical study
European journal of medical research 27(1), 270 () [10.1186/s40001-022-00903-9]  GO OpenAccess  Download fulltext Files BibTeX | EndNote: XML, Text | RIS


CC0: Public Domain Dedication ; OpenAccess

QR Code for this record

The record appears in these collections:
Document types > Other document types
Research data > Datasets
Faculty of Mechanical Engineering (Fac.4)
Publication server / Open Access
Faculty of Medicine (Fac.10)
511001\-4
533500\-3
Public records
Publications database
411110

 Record created 2022-03-03, last modified 2025-07-25


OpenAccess:
Download fulltext XLSX
(additional files)
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)