h1

h2

h3

h4

h5
h6
http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png

Fluid modulated radiofrequency ablation : an ex-vivo study in porcine liver = Flüssigkeitsmodulierte Radiofrequenzablation : Ex-vivo-Versuche in Schweineleber



Verantwortlichkeitsangabevorgelegt von Halina Müller

ImpressumAachen : Publikationsserver der RWTH Aachen University 2012

Umfang87 S. : Ill., graph. Darst.


Aachen, Techn. Hochsch., Diss., 2012


Genehmigende Fakultät
Fak10

Hauptberichter/Gutachter


Tag der mündlichen Prüfung/Habilitation
2012-02-21

Online
URN: urn:nbn:de:hbz:82-opus-40178
URL: https://publications.rwth-aachen.de/record/64626/files/4017.pdf

Einrichtungen

  1. Lehrstuhl für Angewandte Medizintechnik (811001-1)

Inhaltliche Beschreibung (Schlagwörter)
Hochfrequenz-Katheterablation (Genormte SW) ; Leberzellkrebs (Genormte SW) ; Medizin (frei) ; radiofrequency ablation (frei)

Thematische Einordnung (Klassifikation)
DDC: 610

Kurzfassung
Das Ziel dieser Studie war es den Einfluss verschiedener leitfähiger Flüssigkeiten auf den Ablationsvorgang von RFA zu erforschen. Die Arbeitshypothese besagte, dass Flüssigkeiten mit einer hohen Leitfähigkeit die Leitfähigkeit des Gewebes steigern und so eine höhere Energiefreisetzung und größere Koagulationsnekrosen erreicht werden sollte. Für diese Studie wurde folgende Flüssigkeiten verwendet: 0,9% Kochsalzlösung, Magnevist®, Telebrix Gastro®, HAES, 5% Glukoselösung, 95% Ethanol und destilliertes Wasser. Die bipolare RFA wurde an frisch exzidierten Leberproben mit Hilfe des CelonLabPower RF-Systems und der intern gekühlten CelonProSurge T20 Applikationssonde durchgeführt. Vor jedem Ablationsvorgang wurde 1 ml der zu testenden Flüssigkeit in die Probe gespritzt. Während des Ablationsvorgangs wurde die Temperatur durch 2 fieberoptische Temperaturfühler erfasst. Die Impedanz, der Widerstand und die Energiefreisetzung im Gewebe wurde durch die CelonPower Monitor Software erfasst. Zum Schluss wurde die Koagulationsnekrose makroskopisch mit Hilfe eines Lineals ausgemessen. Signifikant größere Koagulationsnekrosen als im Referenzstandard wurden unter der Verwendung von Magnevist®, Telebrix Gastro®, HAES, 5% Glukoselösung, 95% Ethanol erzielt (p>0,001). Das größte Durchschnittsvolumen von 4,83 cm3 wurde unter HAES, das Kleinste im Referenzstandard, mit einem Durchschnitt von 1,42 cm3 erreicht. Ethanol hatte die höchste durchschnittliche Energiezufuhr mit 6,38 kJ, die längste durchschnittliche Ablationszeit betrug mit 5% Glukoselösung 841,40 sek. Die Ergebnisse dieser Studie weisen darauf hin, dass der Einsatz von leitfähigen Flüssigkeiten die thermische und elektrische Leitfähigkeit des Gewebes beeinflussen und so größere Koagulationsnekrosen erzielen können.

The aim of this study was to investigate how the injection of conductive fluids into tissue before RFA, would affect to ablation process. The hypothesis being, that fluids with a high conductivity should enhance tissue conductivity and should therefore increase energy input into the tissue, achieving larger coagulation volumes. The fluids used in this study were: 0.9% Nacl solution, Magnevist®, Telebrix Gastro®, HAES, 5% glucose solution, 95% ethanol and distilled water. Bipolar RFA was carried out on freshly excised porcine liver specimen using a CelonLabPower RF-system and the internally cooled CelonProSurge T20 applicator. Before each ablation process, 1 ml of the fluid to be tested was injected into the specimen using a G21 hypothermic needle. Temperature within the specimen was recorded by inserting two fiberoptic thermocouples parallel to the applicator. Data concerning impedance, resistance and energy input was recorded using the CelonPower Monitor software. After RFA was completed, the specimens were dissected and the lesion size was assessed macroscopically using a ruler. Compared to RFA alone (mean coagulation size 1.42 cm3), significantly larger coagulations (p < 0.001) were achieved using HAES, glucose, Magnevist, TelebrixGastro® and Ethanol. The largest coagulation volumes were achieved with HAES, with a mean volume of 4.83 cm3, the smallest were achieved using RFA alone with a mean volume of 1.42 cm3. The highest energy input was achieved using ethanol with a mean energy input of 6.38 kJ and the longest time of energy application was achieved using 5% glucose solution with a mean heating time of 841.40 sec. Unexpected results were achieved using non-conductive fluids such as glucose solution or distilled water, indicating that the use of any fluid, irrelevant of its conductivity, seems to have an enhancing effect on RFA. This study on fluid-modulated RFA indicates that the injection of conductive fluids can increase the size of coagulation necrosis and energy input, by improving not only electrical conductivity, but possibly also thermal conductivity.

Volltext:
Volltext herunterladen PDF

Dokumenttyp
Dissertation / PhD Thesis

Format
online, print

Sprache
English

Interne Identnummern
RWTH-CONV-125910
Datensatz-ID: 64626

Beteiligte Länder
Germany

 GO


OpenAccess

QR Code for this record

The record appears in these collections:
Dokumenttypen > Qualifikationsschriften > Dissertationen
Publikationsserver / Open Access
Medizinische Fakultät (Fak.10)
Öffentliche Einträge
811001\-1
Publikationsdatenbank

 Datensatz erzeugt am 2013-01-28, letzte Änderung am 2026-06-16


Volltext:
Volltext herunterladen PDF
Dieses Dokument bewerten:

Rate this document:
1
2
3
 
(Bisher nicht rezensiert)