The study was approved by the local Ethics Committee and registered in the German Clinical Trials Register on 22nd of February 2022 (DRKS00027309) prior to inclusion of the first participant. 158 medical professionals were randomized into one of two groups: “no feedback” and “feedback”- group. In both groups, participants carried out three two-minute intervals of cardiopulmonary resuscitation on a manikin at day and at night. Members of the “feedback”-group received guidance by a feedback device. Primary endpoint was the mean compression depth at two time-intervals at the beginning (t1 = 30 – 60s) and the end (t2 = 480-540s) of the experience at night. Secondary endpoints are adequate compression depth (%), compression frequency, correct chest recoil (%), correct hand positon (%), effective compressions (%), mean compression depth, no-flow time, non-sufficient compression depth (%), too deep compression depth and regression analysis of the participants questionaire. A three-factorial ANOVA with two repeated measurement factors (time points day, night; compression cycles, 1 - 3) and the grouping factor feedback and median BMI was performed to analyze secondary endpoints. Post-hoc analysis was carried out with Bonferroni-correction. A p-value <0.05 was considered to indicate a significant deviation from the respective null hypothesis. The secondary endpoint was selected for the linear regression analysis, as not all subject characteristics were applicable where the primary endpoint was concerned. First, a simple linear regression was performed for each parameter, followed by a multiple linear regression analysis. All data were gathered in anonymous form and SPSS (version 29) was used for statistical analyses.

OpenAccess:
Download fulltext PDF
Download fulltext ZIP
(additional files)

Dokumenttyp
Dataset

Format
online

Sprache
English

Interne Identnummern
RWTH-2024-08349
Datensatz-ID: 992681

Beteiligte Länder
Germany

 GO


Related:

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Journal Article  ;  ;  ;  ;  ;  ;  ;
Using an audiovisual feedback device improves cardiopulmonary resuscitation performance during day and night – a randomized controlled simulation study
BMC emergency medicine 25, 95 () [10.1186/s12873-025-01249-1]  GO OpenAccess  Download fulltext Files BibTeX | EndNote: XML, Text | RIS


Creative Commons Attribution CC BY 4.0 ; OpenAccess

QR Code for this record

The record appears in these collections:
Document types > Other document types
Research data > Datasets
Publication server / Open Access
Faculty of Medicine (Fac.10)
535000\-2
Public records
526500\-2
University Hospital
Publications database
9200401

 Record created 2024-09-09, last modified 2025-09-30


OpenAccess:
readme - Download fulltext PDF
10.18154_RWTH-2024 - Download fulltext ZIP
(additional files)
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)